SED-23ZQM-U is a 23 L tabletop pre-vacuum pressure-steam sterilizer (Class II medical device). It uses electric heating and multiple pulsating vacuums for fast heat-up and thorough sterilization, with powerful vacuum dry

Class II medical deviceAir leak rate ≤0.13 kPa/min (EN 13060-aligned)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Distilled water (~0.5–1 L) feeds from the 2 L tank into the electric-heated chamber. The double-head oil-free vacuum pump performs multiple pulsating pre-vacuum cycles (Class B-style) to evacuate air from the Φ246 × 450 mm chamber and load. Saturated steam at 121 °C or 134 °C is then injected; pressure rises to 0.21 MPa with humidity ≥80%. The microcomputer holds for the user-set time, monitored by built-in pressure and temperature sensors. Powerful post-vacuum drying removes moisture (residual <0.2% on instruments, <1% on dressings). Waste steam is condensed in the built-in collector and the cycle ends without external steam release. Micro-printer logs minute-by-minute data; high/low alarms and overpressure protections trigger as needed.

Processus de fonctionnement
1Distilled water (~0.5–1 L) feeds from the 2 L tank into the electric-heated chamber.
2The double-head oil-free vacuum pump performs multiple pulsating pre-vacuum cycles (Class B-style) to evacuate air from the Φ246 × 450 mm chamber and load.
3Saturated steam at 121 °C or 134 °C is then injected; pressure rises to 0.21 MPa with humidity ≥80%.
4The microcomputer holds for the user-set time, monitored by built-in pressure and temperature sensors.
5Powerful post-vacuum drying removes moisture (residual <0.2% on instruments, <1% on dressings).
6Waste steam is condensed in the built-in collector and the cycle ends without external steam release.
7Micro-printer logs minute-by-minute data; high/low alarms and overpressure protections trigger as needed.

Caractéristiques techniques

Caractéristiques de la variante : SED-23ZQM-U

Caractéristiques

Modèle
SED-23ZQM-U
Tension
AC 220V 50Hz
Puissance
1.7 kW

Dimensions

Longueur
715 mm
Largeur
513 mm
Hauteur
425 mm
Poids
49 kg

Matériaux

Matériaux en contact
304 anti-corrosion stainless steel sterilization chamber; silicone door seal ring
Matériaux du bâti
ABS outer casing; 304 stainless steel chamber

Caractéristiques principales

23 L pre-vacuum pressure-steam sterilizer
Multiple pulsating vacuum cycles (faster heat-up, thorough sterilization)
Powerful vacuum drying — instrument residual humidity <0.2%, dressing <1%
6 sterilization modes: bare/wrapped instrument, fabric/hollow, rubber, B&D test, vacuum test
Microcomputer intelligent control with automatic door lock
LCD temperature display
Chamber Φ246 × 450 mm in 304 anti-corrosion stainless steel
ABS outer casing
Double-head oil-free vacuum pump (leather cup)
Built-in pressure sensor
Built-in temperature sensor
Micro-printer (minute-by-minute permanent record)
Built-in condensate collector — internal steam recycling, no external venting
Automatic water-quality monitoring
Silicone seal ring (2-year / 1,200-cycle service life)
Safety valve auto-opens at 250 kPa
Overpressure auto-vent at 220 kPa
Overpressure program-stop and auto-release at 230 kPa
Air leak rate ≤0.13 kPa/min at each test stage
Dynamic chamber pressure change ≤1000 kPa/min in any 2 s
High/low temperature alarm system
Energy consumption ~1.5 kWh per cycle
Power 1.7 kVA, AC 220V 50Hz
Dimensions 715 × 513 × 425 mm, weight 49 kg
Class II medical device

Applications

Surgical, dental and ophthalmic instrument sterilization
Wrapped/encapsulated instrument sterilization
Fabric and hollow load sterilization
Rubber product sterilization
B&D and vacuum-leak validation testing

Secteurs

Hospitals and medical clinics
Dental clinics
Pharmaceutical R&D
Laboratoire
Beauty / aesthetic clinics
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

Class II medical device
Air leak rate ≤0.13 kPa/min (EN 13060-aligned)

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→