Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Machine intégrée de séchage et déshumidification / Drying & Dehumidification Integrated Machine
SED-15HCJ-A
Sur devis
SED-15HCJ-A
SED · SED-15HCJ-A · En vedette

SED-15HCJ-A — Drying & Dehumidification Integrated Machine

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-15HCJ-A Dual-15P Forward-Blow Drying Room (Drying & Dehumidification Integrated Machine). Rated heating 45 kW, rated power 13.8 kW, rated current 25.8 A, 380V/50Hz; rated room temperature 75°C; dehumidification 42 L/

Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Heat-pump-based drying with top-blow forward circulation: heat-pump main unit produces hot dry air which is blown from the top through the supply circulation fan into the drying room over the loaded carts/trays. Saturated air returns from the bottom via return duct to the main unit, where moisture is condensed and removed by the dehumid fan; air is reheated and recirculated. Motorized damper regulates make-up/exhaust air. Closed-loop heat-pump operation gives low energy consumption (15 kWh/h) versus direct heating.

Processus de fonctionnement
1Heat-pump-based drying with top-blow forward circulation: heat-pump main unit produces hot dry air which is blown from the top through the supply circulation fan into the drying room over the loaded carts/trays.
2Saturated air returns from the bottom via return duct to the main unit, where moisture is condensed and removed by the dehumid fan; air is reheated and recirculated.
3Motorized damper regulates make-up/exhaust air.
4Closed-loop heat-pump operation gives low energy consumption (15 kWh/h) versus direct heating.

Caractéristiques techniques

Caractéristiques de la variante : SED-15HCJ-A

Caractéristiques

Modèle
SED-15HCJ-A
Tension
380V/50Hz
Fluides et énergie
380V/50Hz 3-phase; total 31.5 kW; average consumption 15 kWh/h; heat-pump main unit + 9 fans
Puissance
13.8 kW

Dimensions

Longueur
2000 mm
Largeur
1000 mm
Hauteur
2000 mm
Poids
450 kg
Emprise au sol
Main unit 2000 × 1000 × 2000 mm. Drying room 7200 × 4300 × 2550 mm (overall 8100 × 4300 × 2550). Fan frame 2000 × 2000 × 2.

Matériaux

Matériaux en contact
Trays / cart contact surfaces (specific material not stated)
Matériaux du bâti
Drying room with ceiling baffle, air duct, double door; main unit cabinet

Caractéristiques principales

Heat-pump main unit (energy-efficient drying, 15 kWh/h average)
Rated heating 45 kW; rated electrical 13.8 kW
Rated room temperature 75°C
Dehumidification 42 L/h
Drying room 7200×4300×2550 mm (~6900×4100×2000 usable)
9× #6 outer-rotor blowers for forward-blow circulation
Top-blow / bottom-return circulation airflow
Material capacity ~2500 kg/batch
Total system power 31.5 kW
Cart system: 20× carts (1210×870×1750 mm); 640× trays (800×600×50 mm)
Double door 2000×2000 mm for full cart access
Motorized damper, dehumid fan, ceiling baffle, return duct
Integrated heat-pump drying + dehumidification — much lower energy than direct-heat drying
Closed-loop circulation preserves heat
Large 2500 kg batch capacity
Cart/tray system for fast loading and unloading
Forward-blow design with 9 blowers ensures uniform drying across the room
75°C rated room temperature suits heat-tolerant pharmaceuticals/foods/herbs

Applications

Bulk material drying (pharmaceutical/food/herb)
Dehumidification of damp materials
Heat-pump low-temperature drying

Secteurs

Pharmaceutique
Traditional Chinese medicine (TCM)
Food
Agricultural products
Industrial drying
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→