SED-15HCJ-A Dual-15P Forward-Blow Drying Room (Drying & Dehumidification Integrated Machine). Rated heating 45 kW, rated power 13.8 kW, rated current 25.8 A, 380V/50Hz; rated room temperature 75°C; dehumidification 42 L/

Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Heat-pump-based drying with top-blow forward circulation: heat-pump main unit produces hot dry air which is blown from the top through the supply circulation fan into the drying room over the loaded carts/trays. Saturated air returns from the bottom via return duct to the main unit, where moisture is condensed and removed by the dehumid fan; air is reheated and recirculated. Motorized damper regulates make-up/exhaust air. Closed-loop heat-pump operation gives low energy consumption (15 kWh/h) versus direct heating.

Proceso de funcionamiento
1Heat-pump-based drying with top-blow forward circulation: heat-pump main unit produces hot dry air which is blown from the top through the supply circulation fan into the drying room over the loaded carts/trays.
2Saturated air returns from the bottom via return duct to the main unit, where moisture is condensed and removed by the dehumid fan; air is reheated and recirculated.
3Motorized damper regulates make-up/exhaust air.
4Closed-loop heat-pump operation gives low energy consumption (15 kWh/h) versus direct heating.

Especificaciones técnicas

Especificaciones de la variante: SED-15HCJ-A

Especificaciones

Modelo
SED-15HCJ-A
Tensión
380V/50Hz
Suministros
380V/50Hz 3-phase; total 31.5 kW; average consumption 15 kWh/h; heat-pump main unit + 9 fans
Potencia
13.8 kW

Dimensiones

Longitud
2000 mm
Anchura
1000 mm
Altura
2000 mm
Peso
450 kg
Superficie de instalación
Main unit 2000 × 1000 × 2000 mm. Drying room 7200 × 4300 × 2550 mm (overall 8100 × 4300 × 2550). Fan frame 2000 × 2000 × 2.

Materiales

Materiales en contacto
Trays / cart contact surfaces (specific material not stated)
Materiales del cuerpo
Drying room with ceiling baffle, air duct, double door; main unit cabinet

Características principales

Heat-pump main unit (energy-efficient drying, 15 kWh/h average)
Rated heating 45 kW; rated electrical 13.8 kW
Rated room temperature 75°C
Dehumidification 42 L/h
Drying room 7200×4300×2550 mm (~6900×4100×2000 usable)
9× #6 outer-rotor blowers for forward-blow circulation
Top-blow / bottom-return circulation airflow
Material capacity ~2500 kg/batch
Total system power 31.5 kW
Cart system: 20× carts (1210×870×1750 mm); 640× trays (800×600×50 mm)
Double door 2000×2000 mm for full cart access
Motorized damper, dehumid fan, ceiling baffle, return duct
Integrated heat-pump drying + dehumidification — much lower energy than direct-heat drying
Closed-loop circulation preserves heat
Large 2500 kg batch capacity
Cart/tray system for fast loading and unloading
Forward-blow design with 9 blowers ensures uniform drying across the room
75°C rated room temperature suits heat-tolerant pharmaceuticals/foods/herbs

Aplicaciones

Bulk material drying (pharmaceutical/food/herb)
Dehumidification of damp materials
Heat-pump low-temperature drying

Sectores

Farmacéutico
Traditional Chinese medicine (TCM)
Food
Agricultural products
Industrial drying
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→