SED-12PYXT-D coating spray system: auxiliary unit for tablet/pill/granule coating pans. 12 L coating-liquid bucket with separate water layer below for 1 kW electric heating. 40 W peristaltic pump (silicone tube, GMP-frie

GMP-compliant wetted path
Choisir une variante (3)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Coating liquid is held in the upper layer of a 12 L bucket; the lower layer holds water heated by a 1 kW electric heater (must be water-filled before powering up). A pneumatic stirrer driven through an adjustable needle valve mixes the coating liquid. A 40 W peristaltic pump pushes liquid through silicone tubing — liquid never contacts other pump components, meeting GMP. The atomized spray gun (compressed air 0.4-0.6 MPa, 270 L/min) sprays coating liquid onto tablets/pills/granules in the coating pan. Spray on/off cycle is timer-set in HH:MM:SS for both spray and pause periods.

Processus de fonctionnement
1Coating liquid is held in the upper layer of a 12 L bucket; the lower layer holds water heated by a 1 kW electric heater (must be water-filled before powering up).
2A pneumatic stirrer driven through an adjustable needle valve mixes the coating liquid.
3A 40 W peristaltic pump pushes liquid through silicone tubing — liquid never contacts other pump components, meeting GMP.
4The atomized spray gun (compressed air 0.4-0.6 MPa, 270 L/min) sprays coating liquid onto tablets/pills/granules in the coating pan.
5Spray on/off cycle is timer-set in HH:MM:SS for both spray and pause periods.

Caractéristiques techniques

Caractéristiques de la variante : SED-12PYXT-M 12 L variant with 60 W pump

Caractéristiques

Modèle
SED-12PYXT-D
Fluides et énergie
Compressed air 0.4-0.6 MPa, 270 L/min (customer-supplied); single-phase power for 1 kW heater + 40 W pump + controls
Détails de conformité
Coating liquid only contacts silicone tubing (peristaltic pump) — meets pharmaceutical GMP requirements.
Puissance
1.04 kW
Pression d’air
0.4-0.6 MPa compressed air (customer-supplied)

Matériaux

Matériaux en contact
Silicone tubing (peristaltic pump wetted path)

Caractéristiques principales

12 L coating-liquid bucket with separate heated water jacket
1 kW electric water heater (water-filled before use — do not dry-run)
40 W peristaltic pump (silicone tubing, GMP-compliant wetted path)
Pneumatic stirrer with adjustable speed via needle valve
Imported high-atomization spray gun with adjustable spray width
Compressed air 0.4-0.6 MPa, 270 L/min (customer-supplied)
Programmable spray on/off cycle timer (HH:MM:SS)
Casters for easy positioning at any coating pan
Eliminates uneven manual spraying; reduces labor
Silicone-tube-only wetted path — GMP-compliant
Reverse-pump cleaning supported (residual coating blow-back to drain)
Mobile — rolls to any coating pan in the production suite

Applications

Spraying coating film onto tablets, pills, granules
Auxiliary for pharmaceutical coating-pan operations

Secteurs

Pharmaceutical (solid dosage / coating)
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

GMP-compliant wetted path

Nettoyage et entretien

After spraying: open the lower ball valve to drain the coating bucket. Reverse-run the peristaltic pump to expel residual coating liquid from the tubing. Pour cleaning solvent into the bucket and run the pump forward to flush the gun and tubing. Drain the lower water jacket for long-term storage. Wipe machine clean and cover.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→