Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Appareil de force de gel de gélatine (Bloom) / Gelatin Gel Strength Test System with Embedded Micro Printer (Upgrade of SED-10RJC-B)
SED-10RJC2-B
Sur devis
SED-10RJC2-B
SED · SED-10RJC2-B · En vedette

SED-10RJC2-B — Gelatin Gel Strength Test System with Embedded Micro Printer

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-10RJC2-B Gelatin Gel Strength Test System — upgraded version of SED-10RJC-B with an embedded micro printer in the main unit. Complete 3-component system: (1) SED-10RJC2-B gel strength tester main unit with embedded m

GB 6783 — Food additive gelatinGB 13731 — Medicinal hard gelatin capsulesQB 2354 — Medicinal gelatinQB/T 1995 — Industrial gelatinQB/T 1996 — Bone gelatinQB 1997 — Photographic gelatin
Choisir une variante (1)
Délai de livraison
Sur devis
Cadence
5–1000 Bloom g

Fonctionnement

Gel sample (6.67% gelatin) is conditioned in the precision constant-temperature water bath (5–70°C, ±0.1°C) cooled by the refrigeration unit (30°C → 10°C in <40 min). The gel strength tester drives a 12.7 mm cylindrical probe into the gel surface at defined depth to measure force, returning gel strength in Bloom g. Embedded micro printer outputs preset parameters, test results, date, and time for record-keeping.

Processus de fonctionnement
1Gel sample (6.67% gelatin) is conditioned in the precision constant-temperature water bath (5–70°C, ±0.1°C) cooled by the refrigeration unit (30°C → 10°C in <40 min).
2The gel strength tester drives a 12.7 mm cylindrical probe into the gel surface at defined depth to measure force, returning gel strength in Bloom g.
3Embedded micro printer outputs preset parameters, test results, date, and time for record-keeping.

Caractéristiques techniques

Caractéristiques de la variante : SED-10RJC-B (predecessor

Caractéristiques

Modèle
SED-10RJC2-B
Cadence
5–1000 Bloom g
Tension
220V, 50Hz; main unit 60W; bath/chiller 1200W
Puissance
0.06 kW

Dimensions

Longueur
260 mm
Largeur
260 mm
Hauteur
450 mm

Matériaux

Matériaux en contact
Cylindrical probe Ø12.700 ±0.010 mm; SS inner liner of bath
Matériaux du bâti
Steel main unit; stainless steel bath inner liner; bath HW-III (58×44×22 cm); refrigeration ZL-III (48×38×29 cm)

Caractéristiques principales

Three-component system: gel strength tester + cold water bath + refrigeration unit
Embedded micro printer for results, parameters, date & time
Meets 2020 Pharmacopoeia measurement time requirement
Computer dynamic monitoring of probe insertion depth
Test range: 5–1000 Bloom g; accuracy ±0.3%; resolution 1 g; repeatability ±1 Bloom g
Sampling depth 1–60 mm; travel error ≤±0.1 mm
5 sampling speeds (0.1–2.0 mm/s); 4 modes (single-step/hold/cycle/auto)
Standard serial print port + embedded micro printer
Bath temperature range 5–70°C with ±0.1°C accuracy; magnetic pump circulation for uniform temperature
Refrigeration: 30°C → 10°C in <40 min; high-power compressor, low noise
Stainless steel inner liner of bath
Auto detection, auto diagnosis, auto alarm
VFD intelligent temperature control
Complete bench system — tester, bath, and chiller
Embedded micro printer for record-keeping
2020 Pharmacopoeia-compliant

Applications

Gelatin gel strength (Bloom) measurement
QC of food, medicinal, industrial, bone and photographic gelatin

Secteurs

Pharmaceutical (medicinal gelatin / hard gelatin capsules)
Food
Industrial / bone / photographic gelatin
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

GB 6783 — Food additive gelatin
GB 13731 — Medicinal hard gelatin capsules
QB 2354 — Medicinal gelatin
QB/T 1995 — Industrial gelatin
QB/T 1996 — Bone gelatin
QB 1997 — Photographic gelatin
Chinese Pharmacopoeia 2020

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→