SED-100HWX-S High-Temperature Constant-Temperature Test Chamber. 100 L inner volume oven for testing electrical/electronic products and pharmaceutical materials at elevated temperatures (RT+8 to 350 °C). PID-controlled w

GB2423.2-89 Test B — High temperature test method (electrical and electronic basic environmental test)GB/T 5170.2-1996 (electrical/electronic environmental test equipment basic parameter calibration — temperature test equipment)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Nichrome electric heating wire heats air in the inner chamber under PID control via solid-state relay. Internal fan circulates air through the duct system to maintain uniform temperature. Manual damper switches between recirculation and air-exchange modes (adjustable opening). TIM-560 touch-screen controller with programmable segments manages temperature setpoint, ramp, and hold. Safety features: ground-fault breaker, thermal fuse, fan thermal switch, control loop fuse, hi/lo temperature limits.

Processus de fonctionnement
1Nichrome electric heating wire heats air in the inner chamber under PID control via solid-state relay.
2Internal fan circulates air through the duct system to maintain uniform temperature.
3Manual damper switches between recirculation and air-exchange modes (adjustable opening).
4TIM-560 touch-screen controller with programmable segments manages temperature setpoint, ramp, and hold.
5Safety features: ground-fault breaker, thermal fuse, fan thermal switch, control loop fuse, hi/lo temperature limits.

Caractéristiques techniques

Caractéristiques de la variante : SED-100HWX-S

Caractéristiques

Modèle
SED-100HWX-S
Tension
AC 220V

Dimensions

Longueur
850 mm
Largeur
770 mm
Hauteur
950 mm

Matériaux

Matériaux en contact
SUS304 stainless steel (inner chamber)
Matériaux du bâti
Powder-coated steel exterior (standard white); SUS304 inner chamber; polyurethane door insulation; glass-wool body insulation

Caractéristiques principales

Inner chamber 450×450×500 mm (W×D×H), 100 L
Outer dimensions 770×850×950 mm
Two height-adjustable stainless-steel mesh trays (370×405 mm), customizable hole diameter
Tray load capacity 50 kg per layer (customizable)
Temperature range RT+8 to 350 °C (set range RT+10 to 300 °C)
Temperature accuracy: ±1 °C at set point
TIM-560 touch-screen programmable controller
PID + solid-state relay control
Adjustable air exchange damper
Power: AC 220 V; comprehensive safety protection
Schneider France AC contactor and thermal relay
Gute brand solid-state relay
Canada Reels temperature controller
Su brand fan
GB2423.2-89 / GB/T 5170.2-1996 compliance
Comprehensive safety: ground-fault breaker, thermal fuse, fan thermal switch, control loop fuse, hi/lo temperature alarms
Optional: 2 stainless-steel mesh trays (+$100 USD / +¥600 RMB)

Applications

High-temperature aging tests
Electrical and electronic product environmental tests
Pharmaceutical material thermostability tests
Material heat-resistance qualification

Secteurs

Electronics
Electrical appliances
Pharmaceutique
Materials testing labs

Marques des composants

Schneider France (AC contactor, thermal relay)
Gute (solid-state relay)
Canada Reels (temperature controller)
Su brand (fan)
TIM-560 touch-screen controller
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

GB2423.2-89 Test B — High temperature test method (electrical and electronic basic environmental test)
GB/T 5170.2-1996 (electrical/electronic environmental test equipment basic parameter calibration — temperature test equipment)

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→