Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Machine de nettoyage / Large Industrial Parts/Utensil Washer
SED-1000QXJ-H
Sur devis
SED-1000QXJ-H
SED · SED-1000QXJ-H · En vedette

SED-1000QXJ-H — Large Industrial Parts/Utensil Washer

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-1000QXJ-H large industrial parts washer for pharmaceutical and food-industry utensils: glassware,filling-line components,tablet-press parts,stainless filter housings,mixing tanks,fermenters,PP drums,hoses,and fitting

GMPChina Pharmacopoeia 2020 0681 Purified Water conductivity standard
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Utensils loaded on 316L stainless racks are rolled into the chamber on transfer trolleys. The automatic cycle progresses through pre-wash, detergent wash (peristaltic pump dosing), purified-water rinse, WFI rinse, WFI final spray-rinse, and hot-air drying. Conductivity electrode monitors the final rinse to automatically determine the clean endpoint. The sanitary-grade recirculation pump (VFD soft-start) maintains turbulent flow at monitored pressure to ensure wash effectiveness. Hot air passes through two H14 HEPA filters (one high-temp rated to 250 °C, one high-humidity rated) via spray arms on chamber top, bottom, and rack nozzles.

Processus de fonctionnement
1Utensils loaded on 316L stainless racks are rolled into the chamber on transfer trolleys.
2The automatic cycle progresses through pre-wash, detergent wash (peristaltic pump dosing), purified-water rinse, WFI rinse, WFI final spray-rinse, and hot-air drying.
3Conductivity electrode monitors the final rinse to automatically determine the clean endpoint.
4The sanitary-grade recirculation pump (VFD soft-start) maintains turbulent flow at monitored pressure to ensure wash effectiveness.
5Hot air passes through two H14 HEPA filters (one high-temp rated to 250 °C, one high-humidity rated) via spray arms on chamber top, bottom, and rack nozzles.

Caractéristiques techniques

Caractéristiques de la variante : SED-1000QXJ-H

Caractéristiques

Modèle
SED-1000QXJ-H
Tension
380V/50Hz
Tensions prises en charge
380V/50Hz (par défaut)
Fluides et énergie
Purified water: 0.25 MPa, DN25, 50 L/min (50 L per step); WFI: 0.25 MPa, DN25, 50 L/min; compressed air: 0.6 MPa, Φ8; drain: independent metal drain DN50, 50 L/min; exhaust: DN80, 7 m³/min (90 °C, can connect to clean-room plenum); electrical: 380V/50Hz, 24 kW
Détails de conformité
Designed to meet GMP requirements; final-rinse conductivity verified against China Pharmacopoeia 2020 (four parts, 0681) purified-water standard. Supports DQ/IQ/OQ/FAT/SAT/PQ validation.
Puissance
24 kW
Pression d’air
0.6MPa φ8

Dimensions

Longueur
2000 mm
Largeur
1190 mm
Hauteur
2250 mm

Matériaux

Matériaux en contact
SUS316L (chamber Ra ≤ 0.4 µm; piping Ra ≤ 0.6 µm); PTFE (piping fittings)
Matériaux du bâti
SUS316L interior; SUS304 exterior

Caractéristiques principales

1.5D clean-piping design
316L SUS chamber interior, Ra ≤ 0.4 µm; all piping 316L, Ra ≤ 0.6 µm
Sanitary-grade VFD soft-start recirculation pump
Spray-arm monitoring system ensures wash coverage
Pneumatic auto-lifting door with silicon-rubber gas/water seal
39 standard programs + 200 customizable programs
Three-level password management (operator / system admin / parameter admin)
20,000 audit-trail records, exportable as non-editable PDF
Riboflavin spray-coverage test: 100% coverage validated
Two H14 HEPA filters (high-temp 250 °C + high-humidity rated)
Conductivity auto-endpoint detection (China Pharmacopoeia 2020, 0681)
Cleaning temp up to 93 °C; drying temp up to 120 °C, 18 kW water heater + 11.25 kW drying heater
1000 L chamber; 2000×1190×2250 mm (W×D×H)
3 wash racks + 2 transfer trolleys; ~90 min per cycle
PLC Siemens S7-1200 + 7-inch Siemens HMI
Meets GMP + China Pharmacopoeia 2020 purified-water conductivity standard
Complete validation documentation: DQ, IQ, OQ, FAT, SAT (PQ assistance available)
Conductivity auto-endpoint: no manual sampling needed for cycle release
Riboflavin 100% spray-coverage verified
Safe-state protection on power loss; restart requires operator confirmation
Modular design for fast component replacement; self-diagnostic alarm

Applications

Pharmaceutical utensil washing
Food-industry large-vessel cleaning
Filling-line component washing
Tablet-press component washing
Fermenter / mixing tank washing

Secteurs

Pharmaceutique
Food / biotech

Marques des composants

Siemens S7-1200 PLC (Germany)
Siemens 7-inch HMI (Germany)
PT100 temperature sensor — Feiyan / Zibo
MSX differential pressure switch — Dwyer / USA
MIK circulation-water pressure — Meikong / Hangzhou
SS-301211 conductivity electrode — Senshi / Zibo
KS sanitary recirculation pump — Sterling / Beijing
XBL-D pneumatic butterfly valve — Xibeilun / Zhejiang
XBL-2G pneumatic diaphragm valve — Xibeilun / Zhejiang
2RB2 blower — GREENCO / Zhejiang
H14 HEPA filter — Sujin Huatai / Suzhou
683K peristaltic pump — Chongqing Jieheng / Chongqing
EDR switching power supply — Meanwell / Taiwan
316L stainless wash racks; 304 stainless transfer trolleys
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

GMP
China Pharmacopoeia 2020 0681 Purified Water conductivity standard

Nettoyage et entretien

Automated wash cycle performs pre-rinse, detergent wash, purified-water rinse, WFI rinse, WFI final spray-rinse, and hot-air drying (~90 min total). Conductivity endpoint automatic. Manual cleaning: open door, remove racks, rinse 316L chamber and piping.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→