Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Cabine de pesée / Negative-Pressure Weighing / Sampling Booth
SED-1.3-1.3-2.5CLS-Z
Sur devis
SED-1.3-1.3-2.5CLS-Z
SED · SED-1.3-1.3-2.5CLS-Z · En vedette

SED-1.3-1.3-2.5CLS-Z — Negative-Pressure Weighing / Sampling Booth

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-1.3-1.3-2.5CLS-Z is a negative-pressure weighing and sampling booth constructed entirely from SUS304 stainless steel. Overall 1300 × 1300 × 2500 mm (W × D × H); working envelope 1200 × 800 × 2000 mm. Rated airflow 30

Designed to GMP cleanroom standards (Class 100 / ISO 5)
Choisir une variante (1)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Two domestic premium centrifugal fans pull air through three-stage filtration: G4 primary (90%@5 µm), F8 medium (97%@1 µm), and H14 HEPA terminal (99.995%@0.3 µm, liquid-trough sealed). The negative pressure prevents powder from escaping into the room. Air velocity 0.25–0.6 m/s. Differential pressure gauges (0–500 Pa and 0–250 Pa) monitor filter loading. Illumination ≥ 300–500 lux; noise ≤ 75 dB.

Processus de fonctionnement
1Two domestic premium centrifugal fans pull air through three-stage filtration: G4 primary (90%@5 µm), F8 medium (97%@1 µm), and H14 HEPA terminal (99.995%@0.3 µm, liquid-trough sealed).
2The negative pressure prevents powder from escaping into the room.
3Air velocity 0.25–0.6 m/s.
4Differential pressure gauges (0–500 Pa and 0–250 Pa) monitor filter loading.
5Illumination ≥ 300–500 lux; noise ≤ 75 dB.

Caractéristiques techniques

Caractéristiques de la variante : SED-1 larger variant (W1300 × D1700 × H2900

Caractéristiques

Modèle
SED-1.3-1.3-2.5CLS-Z
Tension
AC 380V, 50Hz
Fluides et énergie
Power: AC 380V, 50 Hz, 2 kW; ambient 5–40 °C, RH ≤ 85% non-condensing
Détails de conformité
Built to GMP Class 100 (ISO 5) cleanroom standards; SUS304 throughout. Liquid-trough HEPA seal eliminates bypass leakage. DP gauges allow continuous monitoring.
Puissance
2 kW

Dimensions

Longueur
1300 mm
Largeur
1300 mm
Hauteur
2500 mm
Emprise au sol
1300 × 1300 × 2500 mm (W × D × H) overall; working envelope 1200 × 800 × 2000 mm

Matériaux

Matériaux en contact
SUS304 stainless steel (entire enclosure and working surfaces)
Matériaux du bâti
SUS304 stainless steel throughout

Caractéristiques principales

Class 100 (ISO 5) cleanliness inside working envelope
Negative-pressure design — protects operator and environment
Overall 1300 × 1300 × 2500 mm (W × D × H); working envelope 1200 × 800 × 2000 mm
Three-stage filtration: G4 (90%@5 µm) + F8 (97%@1 µm) + H14 HEPA (99.995%@0.3 µm, liquid-trough sealed)
Rated airflow 3000 m³/h; air velocity 0.25–0.6 m/s
Two domestic premium centrifugal fans
Noise ≤ 75 dB; illumination ≥ 300–500 lux
DP gauges: 0–500 Pa (×1) and 0–250 Pa (×2)
Huichen PLC + KunlunTongtai (KingView) HMI
Inspection port ×1; particle-challenge port ×1; power outlets ×2
SUS304 throughout; power 2 kW
Negative-pressure design protects operators handling hazardous APIs, hormonal, cytotoxic or β-lactam powders
Full SUS304 stainless construction — easy to clean, GMP-compliant
Liquid-trough HEPA seal eliminates filter bypass leakage
Compact 1.3 × 1.3 m footprint fits into existing weighing rooms

Applications

Pharmaceutical raw-material weighing (especially hazardous APIs)
Sampling of incoming raw materials with potent or sensitizing powders
API dispensing operations
Containment for hormonal / cytotoxic / β-lactam powder handling

Secteurs

Fabrication pharmaceutique
API / fine chemical production
Biotechnology

Marques des composants

PLC: Huichen
Touchscreen HMI: KunlunTongtai (KingView)
Fans: domestic premium grade (2 units)
HEPA filter: H14, 99.995%@0.3 µm, liquid-trough sealed
Medium filter: F8 (97%@1 µm)
Primary filter: G4 (90%@5 µm)
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

Designed to GMP cleanroom standards (Class 100 / ISO 5)

Nettoyage et entretien

All-stainless surfaces wipe clean. Replace G4 and F8 filters per schedule. HEPA replacement triggered by DP gauge reaching end-of-life setpoint.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→