SED · SED-1.3-1.3-2.5CLS-Z · Destacado

SED-1.3-1.3-2.5CLS-Z — Negative-Pressure Weighing / Sampling Booth

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-1.3-1.3-2.5CLS-Z is a negative-pressure weighing and sampling booth constructed entirely from SUS304 stainless steel. Overall 1300 × 1300 × 2500 mm (W × D × H); working envelope 1200 × 800 × 2000 mm. Rated airflow 30

Designed to GMP cleanroom standards (Class 100 / ISO 5)
Elegir variante (1)
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Two domestic premium centrifugal fans pull air through three-stage filtration: G4 primary (90%@5 µm), F8 medium (97%@1 µm), and H14 HEPA terminal (99.995%@0.3 µm, liquid-trough sealed). The negative pressure prevents powder from escaping into the room. Air velocity 0.25–0.6 m/s. Differential pressure gauges (0–500 Pa and 0–250 Pa) monitor filter loading. Illumination ≥ 300–500 lux; noise ≤ 75 dB.

Proceso de funcionamiento
1Two domestic premium centrifugal fans pull air through three-stage filtration: G4 primary (90%@5 µm), F8 medium (97%@1 µm), and H14 HEPA terminal (99.995%@0.3 µm, liquid-trough sealed).
2The negative pressure prevents powder from escaping into the room.
3Air velocity 0.25–0.6 m/s.
4Differential pressure gauges (0–500 Pa and 0–250 Pa) monitor filter loading.
5Illumination ≥ 300–500 lux; noise ≤ 75 dB.

Especificaciones técnicas

Especificaciones de la variante: SED-1 larger variant (W1300 × D1700 × H2900

Especificaciones

Modelo
SED-1.3-1.3-2.5CLS-Z
Tensión
AC 380V, 50Hz
Suministros
Power: AC 380V, 50 Hz, 2 kW; ambient 5–40 °C, RH ≤ 85% non-condensing
Detalles de conformidad
Built to GMP Class 100 (ISO 5) cleanroom standards; SUS304 throughout. Liquid-trough HEPA seal eliminates bypass leakage. DP gauges allow continuous monitoring.
Potencia
2 kW

Dimensiones

Longitud
1300 mm
Anchura
1300 mm
Altura
2500 mm
Superficie de instalación
1300 × 1300 × 2500 mm (W × D × H) overall; working envelope 1200 × 800 × 2000 mm

Materiales

Materiales en contacto
SUS304 stainless steel (entire enclosure and working surfaces)
Materiales del cuerpo
SUS304 stainless steel throughout

Características principales

Class 100 (ISO 5) cleanliness inside working envelope
Negative-pressure design — protects operator and environment
Overall 1300 × 1300 × 2500 mm (W × D × H); working envelope 1200 × 800 × 2000 mm
Three-stage filtration: G4 (90%@5 µm) + F8 (97%@1 µm) + H14 HEPA (99.995%@0.3 µm, liquid-trough sealed)
Rated airflow 3000 m³/h; air velocity 0.25–0.6 m/s
Two domestic premium centrifugal fans
Noise ≤ 75 dB; illumination ≥ 300–500 lux
DP gauges: 0–500 Pa (×1) and 0–250 Pa (×2)
Huichen PLC + KunlunTongtai (KingView) HMI
Inspección port ×1; particle-challenge port ×1; power outlets ×2
SUS304 throughout; power 2 kW
Negative-pressure design protects operators handling hazardous APIs, hormonal, cytotoxic or β-lactam powders
Full SUS304 stainless construction — easy to clean, GMP-compliant
Liquid-trough HEPA seal eliminates filter bypass leakage
Compact 1.3 × 1.3 m footprint fits into existing weighing rooms

Aplicaciones

Pharmaceutical raw-material weighing (especially hazardous APIs)
Sampling of incoming raw materials with potent or sensitizing powders
API dispensing operations
Containment for hormonal / cytotoxic / β-lactam powder handling

Sectores

Fabricación farmacéutica
API / fine chemical production
Biotechnology

Marcas de componentes

PLC: Huichen
Touchscreen HMI: KunlunTongtai (KingView)
Fans: domestic premium grade (2 units)
HEPA filter: H14, 99.995%@0.3 µm, liquid-trough sealed
Medium filter: F8 (97%@1 µm)
Primary filter: G4 (90%@5 µm)
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

Designed to GMP cleanroom standards (Class 100 / ISO 5)

Limpieza y mantenimiento

All-stainless surfaces wipe clean. Replace G4 and F8 filters per schedule. HEPA replacement triggered by DP gauge reaching end-of-life setpoint.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→