Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Sistema de detección dinámica de partículas en línea / Online Particle Dynamic Detection System
SED-LZJC-A
Consultar
SED-LZJC-A
SED · SED-LZJC-A · Destacado

SED-LZJC-A — Online Particle Dynamic Detection System

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-LZJC-A remote laser airborne particle counter. 0.5–25 μm particle size range (standard channels 0.5 and 5.0 μm), 28.3 L/min sampling flow (1.0 cfm), 24×7 continuous monitoring. Kanomax pharmaceutical-grade sensor; in

ISO 21501-4NISTChina GMPEU GMP Annex 1FDA cGMPISO 14644-1 Class 5
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

A laser diode illuminates the air sample drawn through the sensor at 28.3 L/min by an external vacuum pump. Particles in the beam scatter light, which is detected by a photodetector; scattering intensity determines particle size. Particles are counted in two standard channels (0.5 μm and 5.0 μm). Concentration data are transmitted via RS-485 MODBUS to the EOM monitoring software, which can trigger multicolour LED alarm indicators and stores up to 3,000 data sets on-board.

Proceso de funcionamiento
1A laser diode illuminates the air sample drawn through the sensor at 28.3 L/min by an external vacuum pump.
2Particles in the beam scatter light, which is detected by a photodetector; scattering intensity determines particle size.
3Particles are counted in two standard channels (0.5 μm and 5.0 μm).
4Concentration data are transmitted via RS-485 MODBUS to the EOM monitoring software, which can trigger multicolour LED alarm indicators and stores up to 3,000 data sets on-board.

Especificaciones técnicas

Especificaciones de la variante: SED-LZJC-A

Especificaciones

Modelo
SED-LZJC-A
Tensión
220V 50Hz 1Φ

Dimensiones

Peso
4 kg

Materiales

Materiales en contacto
316L acero inoxidable; PTFE tubing
Materiales del cuerpo
316L

Características principales

Particle size range 0.5–25 μm
Standard channels 0.5 and 5.0 μm
Sampling flow rate 1.0 cfm (28.3 L/min)
Counting efficiency 50% @0.5 μm; 100% @>0.75 μm (JIS)
Zero count <1 count per 5 minutes
Concentration limit 500,000 particles/ft³ at 5% coincidence loss
Long-life laser diode (>20 years rated)
Internal vacuum source (external vacuum pump driven)
MODBUS RS-485 communication protocol
On-board data storage: 3,000 records
316L stainless steel housing
PoE powered (24 VDC)
Weight 4 kg
Operating temperature 0–50 °C
Resistant to VHP / formaldehyde / ozone disinfection
Compliant with China GMP / EU GMP Annex 1 / FDA cGMP / ISO 14644-1 Class 5
ISO 21501-4 calibrated, NIST traceable
Kanomax sensor — purpose-built for pharmaceutical cleanroom monitoring
2-year warranty on full unit and accessories; 3-year warranty on laser head and sampling tube
Integrates with EOM / CQA monitoring software

Aplicaciones

Dynamic particle monitoring in Grade A/B cleanrooms for sterile pharmaceutical manufacturing
Particle monitoring in critical process zones (filling / stoppering)
Cleanroom environmental monitoring
Continuous GMP-compliant environmental monitoring

Sectores

Farmacéutico
Biopharmaceutical

Marcas de componentes

Kanomax (Japan) — particle sensor
Long-life laser diode — laser source
PTFE tubing — sampling circuit
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

ISO 21501-4
NIST
China GMP
EU GMP Annex 1
FDA cGMP
ISO 14644-1 Class 5
21 CFR Part 11

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→