Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Online-System zur dynamischen Partikelerkennung / Online Particle Dynamic Detection System
SED-LZJC-A
Auf Anfrage
SED-LZJC-A
SED · SED-LZJC-A · Hervorgehoben

SED-LZJC-A — Online Particle Dynamic Detection System

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-LZJC-A remote laser airborne particle counter. 0.5–25 μm particle size range (standard channels 0.5 and 5.0 μm), 28.3 L/min sampling flow (1.0 cfm), 24×7 continuous monitoring. Kanomax pharmaceutical-grade sensor; in

ISO 21501-4NISTChina GMPEU GMP Annex 1FDA cGMPISO 14644-1 Class 5
Lieferzeit
Auf Anfrage
Durchsatz
Kontaktieren Sie uns

Funktionsweise

A laser diode illuminates the air sample drawn through the sensor at 28.3 L/min by an external vacuum pump. Particles in the beam scatter light, which is detected by a photodetector; scattering intensity determines particle size. Particles are counted in two standard channels (0.5 μm and 5.0 μm). Concentration data are transmitted via RS-485 MODBUS to the EOM monitoring software, which can trigger multicolour LED alarm indicators and stores up to 3,000 data sets on-board.

Prozessbeschreibung
1A laser diode illuminates the air sample drawn through the sensor at 28.3 L/min by an external vacuum pump.
2Particles in the beam scatter light, which is detected by a photodetector; scattering intensity determines particle size.
3Particles are counted in two standard channels (0.5 μm and 5.0 μm).
4Concentration data are transmitted via RS-485 MODBUS to the EOM monitoring software, which can trigger multicolour LED alarm indicators and stores up to 3,000 data sets on-board.

Technische Daten

Technische Daten für Variante: SED-LZJC-A

Technische Daten

Modell
SED-LZJC-A
Spannung
220V 50Hz 1Φ

Abmessungen

Gewicht
4 kg

Werkstoffe

Kontaktwerkstoffe
316L Edelstahl; PTFE tubing
Gehäusewerkstoffe
316L

Wesentliche Merkmale

Particle size range 0.5–25 μm
Standard channels 0.5 and 5.0 μm
Sampling flow rate 1.0 cfm (28.3 L/min)
Counting efficiency 50% @0.5 μm; 100% @>0.75 μm (JIS)
Zero count <1 count per 5 minutes
Concentration limit 500,000 particles/ft³ at 5% coincidence loss
Long-life laser diode (>20 years rated)
Internal vacuum source (external vacuum pump driven)
MODBUS RS-485 communication protocol
On-board data storage: 3,000 records
316L stainless steel housing
PoE powered (24 VDC)
Weight 4 kg
Operating temperature 0–50 °C
Resistant to VHP / formaldehyde / ozone disinfection
Compliant with China GMP / EU GMP Annex 1 / FDA cGMP / ISO 14644-1 Class 5
ISO 21501-4 calibrated, NIST traceable
Kanomax sensor — purpose-built for pharmaceutical cleanroom monitoring
2-year warranty on full unit and accessories; 3-year warranty on laser head and sampling tube
Integrates with EOM / CQA monitoring software

Anwendungen

Dynamic particle monitoring in Grade A/B cleanrooms for sterile pharmaceutical manufacturing
Particle monitoring in critical process zones (filling / stoppering)
Cleanroom environmental monitoring
Continuous GMP-compliant environmental monitoring

Branchen

Pharma
Biopharmaceutical

Komponentenhersteller

Kanomax (Japan) — particle sensor
Long-life laser diode — laser source
PTFE tubing — sampling circuit
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

ISO 21501-4
NIST
China GMP
EU GMP Annex 1
FDA cGMP
ISO 14644-1 Class 5
21 CFR Part 11

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→