Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Cabina de pesaje / Weighing Room (Dispensing Booth) — A Variant
SED-2.5-1.5-2.5CLS-A
Consultar
SED-2.5-1.5-2.5CLS-A
SED · SED-2.5-1.5-2.5CLS-A · Destacado

SED-2.5-1.5-2.5CLS-A — A Variant

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-2.5-1.5-2.5CLS-A Negative-pressure dispensing booth (A variant). Outer 2500 x 1500 x 2500 mm, working area 2400 x 900 x 1950 mm (split-modular flat-pack for easy on-site move and install). 304 SS construction (1.2 mm

GMP (new China) compliantISO Class 5 / Class A cleanliness at 0.5 um (microbial <=1 colony/plate/4h)DOP-tested H14 HEPA filter (Aifeitai with test report)Filter test reports, material reports, wind speed / illumination / noise test data, instrument and fan certificates included
Plazo de entrega
Consultar
Capacidad de producción
2799–4665 m3/h (rated supply air)

Funcionamiento

SED-2.5-1.5-2.5CLS-A Negative-pressure dispensing booth (A variant). Outer 2500 x 1500 x 2500 mm, working area 2400 x 900 x 1950 mm (split-modular flat-pack for easy on-site move and install). 304 SS construction (1.2 mm panels, internal Ra <=6 um, external Ra <=8 um). Three-stage filtration: G4 primary (synthetic non-woven, 70% @ 0.5 um), F8 medium (synthetic fiber pocket, 90% @ 0.5 um), and H14 liquid-bath HEPA (Aifeitai, 99.995% @ 0.3 um, DOP-tested per latest GMP). 200-mesh polymer airflow distribution membrane (Suzhou Jiajie). Two 0.85 kW Shanghai Yingda centrifugal fans (3200-4600 m3/h, total pressure 400-270 Pa). 10% air exhausted via top vent through H14 HEPA to maintain interior negative pressure and prevent cross-contamination between APIs. Stainless-steel laser-perforated workbench (8 mm holes, 1.5 mm SS). Acrylic sliding doors (8 mm glass), 8 x Philips T5 9.6 W LED lights (~400 lux). Xinjie PLC + Sinee 2.2 kW VFD (A90-4T9R4B) + Siemens TG765-MT touch screen. Auto airflow regulation, pressure-difference display, real-time wind-speed monitoring, wind-speed range alarm, filter-clogging alarm, 3-level user authority. Wind-speed sensor (WD400, 0-2 m/s), measured at 15 cm below membrane: 0.45 m/s +-20%. Three differential pressure sensors: HEPA 0-500 Pa, F8 0-250 Pa, G4 0-125 Pa. Schneider buzzer for HEPA-clog alarm. Delixi dust-proof outlets (220V, IP65). ISO Class 5 / GMP Class A @ 0.5 um cleanliness, microbial limit <=1 colony/plate/4h. Net weight ~280 kg, noise 75 dB. Rated supply airflow 2799-4665 m3/h (exhaust 700 m3/h, adjustable).

Proceso de funcionamiento
1SED-2.5-1.5-2.5CLS-A Negative-pressure dispensing booth (A variant).
2Outer 2500 x 1500 x 2500 mm, working area 2400 x 900 x 1950 mm (split-modular flat-pack for easy on-site move and install).
3304 SS construction (1.2 mm panels, internal Ra <=6 um, external Ra <=8 um).
4Three-stage filtration: G4 primary (synthetic non-woven, 70% @ 0.5 um), F8 medium (synthetic fiber pocket, 90% @ 0.5 um), and H14 liquid-bath HEPA (Aifeitai, 99.995% @ 0.3 um, DOP-tested per latest GMP).
5200-mesh polymer airflow distribution membrane (Suzhou Jiajie).
6Two 0.85 kW Shanghai Yingda centrifugal fans (3200-4600 m3/h, total pressure 400-270 Pa).
710% air exhausted via top vent through H14 HEPA to maintain interior negative pressure and prevent cross-contamination between APIs.
8Stainless-steel laser-perforated workbench (8 mm holes, 1.5 mm SS).
9Acrylic sliding doors (8 mm glass), 8 x Philips T5 9.6 W LED lights (~400 lux).
10Xinjie PLC + Sinee 2.2 kW VFD (A90-4T9R4B) + Siemens TG765-MT touch screen.
11Auto airflow regulation, pressure-difference display, real-time wind-speed monitoring, wind-speed range alarm, filter-clogging alarm, 3-level user authority.
12Wind-speed sensor (WD400, 0-2 m/s), measured at 15 cm below membrane: 0.45 m/s +-20%.
13Three differential pressure sensors: HEPA 0-500 Pa, F8 0-250 Pa, G4 0-125 Pa.
14Schneider buzzer for HEPA-clog alarm.
15Delixi dust-proof outlets (220V, IP65).
16ISO Class 5 / GMP Class A @ 0.5 um cleanliness, microbial limit <=1 colony/plate/4h.
17Net weight ~280 kg, noise 75 dB.
18Rated supply airflow 2799-4665 m3/h (exhaust 700 m3/h, adjustable).

Especificaciones técnicas

Especificaciones de la variante: SED-2.5-1.5-2.5CLS-A

Especificaciones

Modelo
SED-2.5-1.5-2.5CLS-A
Capacidad de producción
2799–4665 m3/h (rated supply air)
Tensión
380V 50Hz
Potencia
3 kW

Dimensiones

Longitud
2500 mm
Anchura
1500 mm
Altura
2500 mm
Peso
280 kg
Superficie de instalación
2500 x 1500 mm (footprint); total height 2500 mm

Materiales

Materiales en contacto
304 stainless steel (panels 1.2 mm; workbench 1.5 mm laser-perforated phi 8 mm); acrylic 8 mm
Materiales del cuerpo
304 acero inoxidable (1.2 mm; internal Ra <=6 um, external Ra <=8 um); acrylic sliding doors with square-tube frame

Características principales

Split-modular flat-pack construction for easy on-site assembly
Three-stage filtration: G4 + F8 + H14 (99.995% @ 0.3 um, liquid-bath, DOP-tested)
200-mesh polymer airflow distribution membrane (Suzhou Jiajie)
Top exhaust (10%) through H14 HEPA maintains interior negative pressure
Twin 0.85 kW Shanghai Yingda centrifugal fans (3200-4600 m3/h)
Sinee 2.2 kW VFD + Siemens TG765-MT touch screen + Xinjie PLC
Wind-speed sensor WD400 (0-2 m/s); setpoint 0.45 m/s +-20% at 15 cm below membrane
Three differential pressure sensors: HEPA 0-500 Pa, F8 0-250 Pa, G4 0-125 Pa
Auto airflow regulation with filter-clogging alarm and 3-level user authority
Schneider buzzer for HEPA-clog alarm
304 SS laser-perforated workbench (8 mm holes)
Acrylic sliding doors with 8 mm glass
8x Philips T5 9.6 W integrated LED lights (~400 lux)
Delixi IP65 dust-proof outlets (220V)
ISO Class 5 / GMP Class A cleanliness at 0.5 um with microbial count <=1 colony/plate/4h
Compliant with new China GMP
Premium components: Aifeitai filters, Shanghai Yingda fans, Siemens HMI, Schneider buzzer, Philips lighting, Delixi outlets
Documents provided: equipment manual, certificate of conformity, filter test reports, material reports, wind speed/illumination/noise test data, instrument and fan certificates — aiding new GMP certification
1-year warranty; 50% advance payment, 50% before delivery

Aplicaciones

Negative-pressure API dispensing
Sub-packaging and weighing under microgrid clean environment

Sectores

Pharmaceutical API and finished-dose dispensing
Sterile / aseptic dispensing
Laboratory weighing

Marcas de componentes

Body / cabinet panels (SUS304 1.2 mm)
Jinya/
H14 edge liquid-bath HEPA filter
Aifeitai/
F8 medium filter pocket
Aifeitai/
G4 primary filter
Aifeitai/
Polymer airflow distribution membrane (200 mesh)
Suzhou Jiajie/
Centrifugal fan (0.85 kW, 3200-4600 m3/h)
Shanghai Yingda/
Lighting (T5 9.6 W integrated)
Philips
PLC
Xinjie/
VFD (A90-4T9R4B 2.2 kW)
Sinee/
Touch screen (TG765-MT)
Siemens
Wind-speed sensor (WD400) and pressure sensors (MSZW101/102/103)
Huayu/
Relays / breakers / power / illumination / e-stop buttons
CHINT/
Buzzer (HEPA-clog alarm)
Schneider
Dust-proof outlet (220V IP65)
Delixi/
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

GMP (new China) compliant
ISO Class 5 / Class A cleanliness at 0.5 um (microbial <=1 colony/plate/4h)
DOP-tested H14 HEPA filter (Aifeitai with test report)
Filter test reports, material reports, wind speed / illumination / noise test data, instrument and fan certificates included

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→