Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Autoclave de vacío pulsante / SED-2.0MM-J Pulsating Vacuum + Water-Bath Dual-Use Sterilizer (with Safety Inspection Interface)
SED-2.0MM-J
Consultar
SED-2.0MM-J
SED · SED-2.0MM-J · Destacado

SED-2.0MM-J — SED-2.0MM-J Pulsating Vacuum + Water-Bath Dual-Use Sterilizer

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-2.0MM-J Pulsating Vacuum + Water-Bath Dual-Use Sterilizer (with GMP validation/safety inspection interface). Horizontal pass-through autoclave with double-door (pneumatic motorised, gas-sealed, double-door interlocke

China GMP (2010 revision)China Pharmacopoeia 2020 editionGB/T 150.1–150.4-2011 pressure vesselsYY 0085.1-1992 Pulsating vacuum pressure steam sterilizerGB 18278.1-2015 industrial moist-heat sterilizationISO standard
Plazo de entrega
Consultar
Capacidad de producción
600 L (chamber 1340x1000x1500 mm)

Funcionamiento

Saturated-steam sterilization with pulsating-vacuum air removal. Horizontal double-jacketed chamber: jacket pre-heated by 0.3–0.5 MPa industrial steam, then alternating pulsed vacuum + pure steam (multiple cycles) removes residual cold air before sterilization hold. After hold, vacuum drying + jacket-heated drying removes moisture. Water-bath mode: clean steam + air mixed overpressure with water immersion/spray for liquid loads in sealed containers. Full GMP validation interface with Siemens MES data extraction port. Cycle: preparation → preheat → vacuum → heat-up → sterilization → drying → end.

Proceso de funcionamiento
1Saturated-steam sterilization with pulsating-vacuum air removal.
2Horizontal double-jacketed chamber: jacket pre-heated by 0.3–0.5 MPa industrial steam, then alternating pulsed vacuum + pure steam (multiple cycles) removes residual cold air before sterilization hold.
3After hold, vacuum drying + jacket-heated drying removes moisture.
4Water-bath mode: clean steam + air mixed overpressure with water immersion/spray for liquid loads in sealed containers.
5Full GMP validation interface with Siemens MES data extraction port.
6Cycle: preparation → preheat → vacuum → heat-up → sterilization → drying → end.

Especificaciones técnicas

Especificaciones de la variante: SED-2.0MM-J

Especificaciones

Modelo
SED-2.0MM-J
Capacidad de producción
600 L (chamber 1340x1000x1500 mm)
Tensión
AC 380V 50Hz
Potencia
4.5 kW
Presión de aire
Compressed air 0.5-0.7 MPa (oil-free, water-free, dust-free); clean compressed air 0.2-0.3 MPa; pure steam 0.2-0.4 MPa; industrial steam 0.3-0.5 MPa (also stated 0.4-0.6 MPa); water 0.1-0.3 MPa

Dimensiones

Longitud
1640 mm
Anchura
2060 mm
Altura
2200 mm
Peso
2300 kg

Materiales

Materiales en contacto
316L stainless steel (inner chamber, door, instrument-side piping, internal safety valve, sterilizing carts); medical-grade silicone rubber (door gasket); medical/food-grade gaskets and O-rings
Materiales del cuerpo
304 stainless steel jacket (autogenous gas-shielded full weld); 304 SS outer decorative panels; aluminium-silicate fibre insulation 60 mm (chlorine-free, asbestos-free)

Características principales

Dual-use: pulsating-vacuum (steam) + water-bath sterilization in one machine
Pass-through double-door (motorised, gas-seal, interlocked) with pressure safety interlock
Pulsating vacuum air removal + vacuum drying + jacket-heated drying
316L SS inner chamber with chamfered/radius corners (no dead angles); 304 SS jacket (full autogenous weld)
ASCO (USA) angle-seat pneumatic valves rated 4M cycles (clamp connection, PTFE seal, 184°C steam rated)
Siemens S7 PLC (50,000 h MTBF) + touch screen + micro-printer (Epson chip) + paperless recorder
Swiss HUBA pressure transmitter + AIRIS Pt100 A-grade sensors (error ≤0.15°C)
Vacuum leak test: evacuate to −90 kPa, pump off 10 min, leakage ≤1.3 kPa
Sterilization time 0–600 min adjustable; temperature uniformity ≤±1°C
MES/network interface (Siemens extraction port) for data connectivity
Dual-use pulsating-vacuum + water-bath capability in a single pass-through autoclave
Imported precision components: Siemens PLC, ASCO valves, HUBA pressure transmitter, AIRIS temperature probes
Designed per Chinese cGMP, GB/T 150 pressure vessel, YY 0085.1, GB 18278.1, ISO and CE
GMP validation interface with DQ/IQ/OQ/PQ documentation support
Network/MES interface (Siemens extraction) for real-time data archiving

Aplicaciones

Sterilization of surgical instruments and metal tools
Sterilization of dressings and sterile garments / textiles
Liquid (culture media) sterilization
Glassware sterilization
Bowie & Dick steam-penetration test
GMP validation runs (IQ/OQ/PQ)

Sectores

Hospitals
Fabricación farmacéutica
Veterinary drug manufacturing (per GMP 2020 vet)
Scientific / experimental animal research

Marcas de componentes

Angle-seat pneumatic valve (clamp, PTFE, 4M cycles, 184°C rated)
ASCO
Water-ring vacuum pump (direct-coupled, mechanical seal, low noise)
Yulong
Circulation pump
WILO
Plate heat exchanger
Huisituo
Air filter (0.22 µm, sterile grade)
Jiangsu Santong
Solenoid valve
AirTAC
Steam trap
CIS
Pressure gauge
Brady (Beijing)
Safety valve (0.1–0.3 MPa)
Guangyi (Zhejiang)
Spray nozzle (spiral, large flow, wide angle, non-clogging)
Sborun
PLC (S7 series, 50,000 h MTBF)
Siemens
Touch screen
TER
Micro printer (Epson chip, sterilization report + temp trend)
Weihuan (Beijing)
Paperless recorder
Unspecified
Pressure transmitter (high precision, anti-interference)
HUBA
Temperature probe (Pt100, A-grade, ≤0.15°C error)
AIRIS (Airuisi)
Sterilizing carts (316L SS, 2 units)
SED
Transport carts (304 SS, 2 units)
SED
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

China GMP (2010 revision)
China Pharmacopoeia 2020 edition
GB/T 150.1–150.4-2011 pressure vessels
YY 0085.1-1992 Pulsating vacuum pressure steam sterilizer
GB 18278.1-2015 industrial moist-heat sterilization
ISO standard
CE standard
GB 50447-2008, GB 14952-2010 (animal research facility)
GMP validation interface (DQ/IQ/OQ/PQ documentation)

Limpieza y mantenimiento

316L SS internal surfaces with chamfered corners and no dead angles for easy cleaning; silicone rubber door gasket cleaned with ordinary surface cleaning (no lubrication required)

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→