SED-1200JNC-A — High-Accuracy Automatic Weight Inspection

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-1200JNC-A capsule checkweigher individually weighs and rejects out-of-spec capsules. Can be used stand-alone with manual loading or in-line after a capsule filling machine via an elevator. No mold change required — a

GMP-compliant
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

High-precision load cells are used; the weighing platform is formed as an inclined chute so capsules slide downward by gravity across the scale. A proprietary algorithm rapidly and accurately calculates each capsule weight. Capsules within spec continue to slide into the accepted product bin; out-of-spec capsules are stopped by a rejection cylinder and fall into a reject bin. Feed uses vibrating corrugated plate to distribute capsules into lanes; a patented single-file bridge queues capsules one-by-one into the weighing platform.

Proceso de funcionamiento
1High-precision load cells are used; the weighing platform is formed as an inclined chute so capsules slide downward by gravity across the scale.
2A proprietary algorithm rapidly and accurately calculates each capsule weight.
3Capsules within spec continue to slide into the accepted product bin; out-of-spec capsules are stopped by a rejection cylinder and fall into a reject bin.
4Feed uses vibrating corrugated plate to distribute capsules into lanes; a patented single-file bridge queues capsules one-by-one into the weighing platform.

Especificaciones técnicas

Especificaciones de la variante: SED-1200JNC-A

Especificaciones

Modelo
SED-1200JNC-A
Tensión
220V, 50Hz
Suministros
Power: 220V/50Hz; compressed air: 0.4–0.6 MPa (auto-alarm and stop if pressure falls below threshold)
Detalles de conformidad
Complies with GMP requirements for cleaning, disinfection, and sterilization. All product-contact materials are 316 SS or pharmaceutical-grade materials — no reaction, adsorption, or release with pharmaceuticals. Equipment passed EMC, environmental, safety, and aging performance tests.
Presión de aire
0.4-0.6 MPa

Materiales

Materiales en contacto
316L acero inoxidable; pharmaceutical-grade PTFE
Materiales del cuerpo
304 acero inoxidable; 316L acero inoxidable

Características principales

12 active weighing channels
Stable throughput 70,000 capsules/hour
Capsule weight detection range 0–2000 mg
Dynamic detection precision ±0.8–2.0 mg
Display resolution 0.1 mg
12-inch industrial touchscreen — rotatable 320°
Machine height adjustable ±50 cm
USB and Ethernet interfaces; supports Modbus-TCP protocol
Three-level user permission management
Data storage for 1 year; supports PC export
Light + audible alarm function
Auto tare (auto-zeroing of scale)
Built-in vibration suppression (suitable for 1st floor and above workshops)
Online sampling inspection / validation function
One mold fits all empty and filled hard capsule sizes
Fully GMP-compliant for cleaning, disinfection, and sterilization; easy to validate
Product-contact parts are minimal and can be removed by one person in minutes for water cleaning
No rotating parts, no lubrication, no contamination, no noise
Half-capsules, broken capsules, double-capped, and deformed capsules do not block channels
Inclined scale platform — no capsule-transport mechanism; load cell is permanently safe and reliable
Sensor module and software fully in-house — low replacement/maintenance cost
Capsule powder does not accumulate (chute offset below material mechanism + inclined layout)
PCB manufactured on Japanese SMT line; EMC/environment/safety/aging fully tested
Can be used stand-alone offline or in-line with filling machine

Aplicaciones

100% individual capsule weight inspection
Empty capsule inspection and rejection
Filled capsule weight inspection and rejection
Tablet weight inspection (with optional tablet mold)

Sectores

Farmacéutico
Capsule production
Tablet production

Marcas de componentes

SYNTRON — linear vibrator BF-01-C
Chuangyou — vibration controller CUH-SDC=VC34-MR-CN
Advantech — 12-inch industrial panel PC PPC-3170-RE4BE
Siprinte — printer SP-D10-40-VSH
SMC (China) — linear cylinder CJ2B10-20Z
SMC (China) — solenoid valve SS5Y3-10F1-18B-C6
igus — rejection cylinder
MEAN WELL — switching power supply NDR-120-24V
Honeywell — power auto-switch HMSL-2C6 / power switch VCF01C/20A
Huawei — wireless data card WiFi2 mini
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

GMP-compliant

Limpieza y mantenimiento

Product-contact parts can be safely removed by one person in minutes and washed with water directly. All channels can be cleaned within 30 minutes. Single-channel disassembly/replacement within 1 hour. All product-contact internal surfaces are polished.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→