Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Espectrofotómetro ultravioleta-visible / UV-Visible Spectrophotometer (Ratio Dual-Beam, 8-inch Touchscreen)
SED-1100FGDJ2-Y
Consultar
SED-1100FGDJ2-Y UV-Visible Spectrophotometer
SED · SED-1100FGDJ2-Y · 1 unidades vendidas

SED-1100FGDJ2-Y — UV-Visible Spectrophotometer

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-1100FGDJ2-Y UV-Visible Spectrophotometer. Ratio dual-beam (Czerny-Turner, 160 mm focal length) optical structure with high-performance blazed holographic grating monochromator (1200 line/mm), 8-inch color touch LCD d

Elegir variante (3)
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Ratio dual-beam Czerny-Turner monochromator (160 mm focal length) with 1200 line/mm blazed holographic grating disperses light from a flange-positioned imported deuterium lamp (UV) and OSRAM tungsten lamp (visible) — source switch at 340 nm. The monochromatic beam is split into sample and reference paths, simultaneously detected by imported photodetectors; the instrument computes the intensity ratio eliminating source-drift errors. Auto 8-cell cuvette changer enables sequential multi-sample measurement. UVwin8 software (USB) provides enhanced data handling, mass storage, and secondary development capability. Power-off memory retains test data, spectra, regression equations, and calibration corrections for rapid re-initialization.

Proceso de funcionamiento
1Ratio dual-beam Czerny-Turner monochromator (160 mm focal length) with 1200 line/mm blazed holographic grating disperses light from a flange-positioned imported deuterium lamp (UV) and OSRAM tungsten lamp (visible) — source switch at 340 nm.
2The monochromatic beam is split into sample and reference paths, simultaneously detected by imported photodetectors; the instrument computes the intensity ratio eliminating source-drift errors.
3Auto 8-cell cuvette changer enables sequential multi-sample measurement.
4UVwin8 software (USB) provides enhanced data handling, mass storage, and secondary development capability.
5Power-off memory retains test data, spectra, regression equations, and calibration corrections for rapid re-initialization.

Especificaciones técnicas

Especificaciones de la variante: SED-1100FGDJ2-Y (standard)

Especificaciones

Modelo
SED-1100FGDJ2-Y
Tensión
AC 220V +/- 22V, 50 Hz +/- 1 Hz
Suministros
AC 220 V ±22 V, 50 Hz ±1 Hz; rated power 200 W; USB connection to PC for UVwin8 software
Potencia
0.2 kW

Dimensiones

Superficie de instalación
Benchtop instrument; mains-powered

Características principales

Wavelength range: 190–1100 nm
Wavelength accuracy: ±0.3 nm
Wavelength repeatability: ≤0.1 nm
Spectral bandwidth: 1.8 nm
Photometric range: 0.0–200.0 %T; –0.301 to 4.000 A; 0.000–9999 C
Photometric accuracy: ±0.3 %T; ±0.002 Abs (0–0.5 A); ±0.004 Abs (0.5–1 A)
Photometric repeatability: ≤0.15 %T; 0.001 Abs (0–0.5 A); 0.002 Abs (0.5–1 A)
Stray light: ≤0.03 %T @220 nm (NaI) and @360 nm (NaNO₂)
Baseline flatness: ≤±0.0015 A
Source switch wavelength: 340 nm
8-inch color touchscreen; USB + UVwin8 software
Auto 8-position cuvette changer
Imported long-life flanged D2 lamp (2-screw quick-change) + OSRAM tungsten lamp
Ratio dual-beam optics for high stability and reproducibility
Imported long-life lamps with tool-less 2-screw D2 lamp replacement
Automatic 8-cell cuvette holder for efficient batch testing
PC integration via UVwin8 software — mass storage, enhanced data processing, secondary development
Power-off memory retains all test data and settings for fast restart
8-inch large color touchscreen for comfortable operation

Aplicaciones

UV-Vis spectrophotometric analysis (absorbance/transmittance)
Concentration direct readout with calibration curves
Kinetic time scans
Full and segmented wavelength scans (S variant only)
Peak-valley detection

Sectores

Pharmaceutical QC and R&D
Chemical analysis
Environmental analysis
Food and beverage QC
Laboratory R&D

Marcas de componentes

Tungsten lamp: OSRAM
Deuterium lamp: imported long-life flanged type
Detector: imported
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→