SED-1100FGDJ2-Y UV-Visible Spectrophotometer. Ratio dual-beam (Czerny-Turner, 160 mm focal length) optical structure with high-performance blazed holographic grating monochromator (1200 line/mm), 8-inch color touch LCD d

Variante wählen (3)
Lieferzeit
Auf Anfrage
Durchsatz
Kontaktieren Sie uns

Funktionsweise

Ratio dual-beam Czerny-Turner monochromator (160 mm focal length) with 1200 line/mm blazed holographic grating disperses light from a flange-positioned imported deuterium lamp (UV) and OSRAM tungsten lamp (visible) — source switch at 340 nm. The monochromatic beam is split into sample and reference paths, simultaneously detected by imported photodetectors; the instrument computes the intensity ratio eliminating source-drift errors. Auto 8-cell cuvette changer enables sequential multi-sample measurement. UVwin8 software (USB) provides enhanced data handling, mass storage, and secondary development capability. Power-off memory retains test data, spectra, regression equations, and calibration corrections for rapid re-initialization.

Prozessbeschreibung
1Ratio dual-beam Czerny-Turner monochromator (160 mm focal length) with 1200 line/mm blazed holographic grating disperses light from a flange-positioned imported deuterium lamp (UV) and OSRAM tungsten lamp (visible) — source switch at 340 nm.
2The monochromatic beam is split into sample and reference paths, simultaneously detected by imported photodetectors; the instrument computes the intensity ratio eliminating source-drift errors.
3Auto 8-cell cuvette changer enables sequential multi-sample measurement.
4UVwin8 software (USB) provides enhanced data handling, mass storage, and secondary development capability.
5Power-off memory retains test data, spectra, regression equations, and calibration corrections for rapid re-initialization.

Technische Daten

Technische Daten für Variante: SED-1100FGDJ2-Y (standard)

Technische Daten

Modell
SED-1100FGDJ2-Y
Spannung
AC 220V +/- 22V, 50 Hz +/- 1 Hz
Versorgung
AC 220 V ±22 V, 50 Hz ±1 Hz; rated power 200 W; USB connection to PC for UVwin8 software
Leistung
0.2 kW

Abmessungen

Aufstellfläche
Benchtop instrument; mains-powered

Wesentliche Merkmale

Wavelength range: 190–1100 nm
Wavelength accuracy: ±0.3 nm
Wavelength repeatability: ≤0.1 nm
Spectral bandwidth: 1.8 nm
Photometric range: 0.0–200.0 %T; –0.301 to 4.000 A; 0.000–9999 C
Photometric accuracy: ±0.3 %T; ±0.002 Abs (0–0.5 A); ±0.004 Abs (0.5–1 A)
Photometric repeatability: ≤0.15 %T; 0.001 Abs (0–0.5 A); 0.002 Abs (0.5–1 A)
Stray light: ≤0.03 %T @220 nm (NaI) and @360 nm (NaNO₂)
Baseline flatness: ≤±0.0015 A
Source switch wavelength: 340 nm
8-inch color touchscreen; USB + UVwin8 software
Auto 8-position cuvette changer
Imported long-life flanged D2 lamp (2-screw quick-change) + OSRAM tungsten lamp
Ratio dual-beam optics for high stability and reproducibility
Imported long-life lamps with tool-less 2-screw D2 lamp replacement
Automatic 8-cell cuvette holder for efficient batch testing
PC integration via UVwin8 software — mass storage, enhanced data processing, secondary development
Power-off memory retains all test data and settings for fast restart
8-inch large color touchscreen for comfortable operation

Anwendungen

UV-Vis spectrophotometric analysis (absorbance/transmittance)
Concentration direct readout with calibration curves
Kinetic time scans
Full and segmented wavelength scans (S variant only)
Peak-valley detection

Branchen

Pharmaceutical QC and R&D
Chemical analysis
Environmental analysis
Food and beverage QC
Laboratory R&D

Komponentenhersteller

Tungsten lamp: OSRAM
Deuterium lamp: imported long-life flanged type
Detector: imported
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→