Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Generador de ultrasonidos / Digital-Pulse-Drive Ultrasonic Generator (Digital-Display Module Type)
SED-1.5CSQ-C
Consultar
SED-1.5CSQ-C
SED · SED-1.5CSQ-C · Destacado

SED-1.5CSQ-C — Digital-Pulse-Drive Ultrasonic Generator

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-1.5CSQ-C is a digital-pulse-drive ultrasonic generator in digital-display module format. Uses internationally advanced digital pulse drive technology: compared to traditional self-oscillating designs, it is more comp

Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Digital pulse drive replaces traditional self-oscillating topology. A frequency-tracking control loop keeps drive frequency locked to the transducer's resonant peak. Coarse frequency selection via toggle switch (20/25/28/40 kHz bands); fine trim via potentiometer W1. Power controlled by separate potentiometer. Timer: in time-display mode, press INC/DEC (long press) to set cleaning time; press ENTER to start timed cycle; set to 999 for continuous operation. FUNC key toggles between frequency and time display (ultrasonic pauses during toggle). Output current must not exceed rated maximum — size at 0.15 A/head for small arrays, 0.12 A/head for large arrays. Fault repair flowchart covers fan on / no ultrasonic, rectifier bridge check, transducer insulation check.

Proceso de funcionamiento
1Digital pulse drive replaces traditional self-oscillating topology.
2A frequency-tracking control loop keeps drive frequency locked to the transducer's resonant peak.
3Coarse frequency selection via toggle switch (20/25/28/40 kHz bands); fine trim via potentiometer W1.
4Power controlled by separate potentiometer.
5Timer: in time-display mode, press INC/DEC (long press) to set cleaning time; press ENTER to start timed cycle; set to 999 for continuous operation.
6FUNC key toggles between frequency and time display (ultrasonic pauses during toggle).
7Output current must not exceed rated maximum — size at 0.15 A/head for small arrays, 0.12 A/head for large arrays.
8Fault repair flowchart covers fan on / no ultrasonic, rectifier bridge check, transducer insulation check.

Especificaciones técnicas

Especificaciones de la variante: SED-1.5CSQ-C

Especificaciones

Modelo
SED-1.5CSQ-C
Tensión
AC mains (well-grounded; not specified, typically 220V)
Suministros
Power: AC mains (typically 220V), well-grounded; max input current governed by transducer head count (0.15 A/head; 0.12 A/head for large arrays)
Detalles de conformidad
Operates from properly-grounded AC mains. Protections: over-current, over-temperature, output short-circuit. Generator protective earth must be properly grounded.

Dimensiones

Superficie de instalación
Allow ≥300 mm clearance behind chassis for fan exhaust

Características principales

Digital-pulse drive — vs traditional self-oscillating: compact, light, high power, stable
Built-in frequency tracking — keeps transducer at resonant peak throughout cycle
Frequency coverage: 20 / 25 / 28 / 40 / 80 / 120 / 200 kHz selectable
Output power continuously adjustable 0–100% via potentiometer
Timer 0–999 (999 = continuous mode); ENTER saves and starts timed cycle
FUNC key cycles between frequency and time display
Current sizing: 0.15 A/head (small arrays), 0.12 A/head (large arrays)
Protections: over-current, over-temperature, output short-circuit
Rear ventilation fan; ≥300 mm clearance required behind chassis
Power stage: transistor (IGBT or MOSFET); rectifier: bridge rectifier
Modern digital-pulse drive — compact, lightweight, high power, stable vs self-oscillating
Frequency tracking maximizes transducer cavitation efficiency
Wide 20–200 kHz coverage in one platform
Robust short-circuit / over-current / over-temperature protection

Aplicaciones

Driving ultrasonic transducers in industrial cleaning baths
Pharmaceutical and lab glassware ultrasonic cleaning
Replacement for older self-excited generators
Multi-head ultrasonic systems (sized at 0.12–0.15 A/head)

Sectores

Pharmaceutical manufacturing (vial / glassware cleaning)
Electronics / semiconductor parts cleaning
Metal parts manufacturing
Laboratory and research

Marcas de componentes

Power stage: transistor (likely IGBT or MOSFET)
Rectifier: bridge rectifier
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Limpieza y mantenimiento

Place in dry, ventilated location with ≥300 mm clearance behind chassis for fan exhaust. Do not exceed rated maximum output current — will damage generator. Do not open chassis; contact qualified service personnel for faults. Protective earth must be properly grounded.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→