SED-PH-S benchtop pH meter with 5.7-inch high-resolution LCD. Measures pH (-2.00 to 20.00, 0.01 resolution, ±0.01 pH accuracy), mV (-2000 to 2000 mV, 0.1 mV resolution, ±0.1% or ±0.3 mV) and temperature (-5 to 110 °C, 0.

GLP-compliant data managementIP54 ingress protection
Lieferzeit
Auf Anfrage
Durchsatz
Kontaktieren Sie uns

Funktionsweise

A glass pH electrode (BNC/Q9 input) is immersed in the sample solution; the electrode generates a potential proportional to H+ activity. The instrument amplifies this mV signal, applies temperature compensation from a 4-pin aviation connector temperature probe (ATC) or manual setting (VTC), and converts to pH using the slope and offset derived from the most recent buffer calibration. Auto-hold senses signal stability and locks the reading; results stream to the on-board GLP-compliant 500-record memory and out via USB or RS-232.

Prozessbeschreibung
1A glass pH electrode (BNC/Q9 input) is immersed in the sample solution; the electrode generates a potential proportional to H+ activity.
2The instrument amplifies this mV signal, applies temperature compensation from a 4-pin aviation connector temperature probe (ATC) or manual setting (VTC), and converts to pH using the slope and offset derived from the most recent buffer calibration.
3Auto-hold senses signal stability and locks the reading; results stream to the on-board GLP-compliant 500-record memory and out via USB or RS-232.

Technische Daten

Technische Daten für Variante: SED-PH-S

Technische Daten

Modell
SED-PH-S
Spannung
AC adapter 100-240V AC input, 9V DC output
Versorgung
External AC adapter accepts 100–240V AC, outputs 9V DC — no special electrical install. No water or air required.
Konformitätsangaben
GLP-compliant data management with date/time stamping. Buffer support for NIST, GB (Chinese national) and DIN buffer sets. IP54 housing.

Abmessungen

Länge
242 mm
Breite
195 mm
Höhe
68 mm
Gewicht
0.9 kg
Aufstellfläche
Benchtop 242 × 195 × 68 mm, 900 g. Sits on any lab bench near a sample station; optional electrode stand sold separately.

Werkstoffe

Kontaktwerkstoffe
Glass / Ag-AgCl pH electrode (sample-contact)

Wesentliche Merkmale

5.7-inch high-resolution backlit LCD display
pH range -2.00 to 20.00, resolution 0.01, accuracy ±0.01 pH
mV range -2000 to 2000 mV, resolution 0.1 mV, accuracy ±0.3 mV or ±0.1%
Temperature -5 to 110 °C, resolution 0.1 °C, accuracy ±0.2 °C (electronic unit), ±0.4 °C (0–60 °C range instrument)
Automatic / manual temperature compensation (ATC / VTC)
Up to 5-point calibration with auto buffer recognition (NIST, GB, DIN)
User-customisable buffer values
Auto-hold endpoint detection (Fast / Medium / Slow), timed and continuous read modes
GLP data management with 500-result memory and date/time stamping
USB 2.0 (flash drive / PC) and RS-232 (printer) outputs
Auto electrode diagnostics with slope / offset display
IP54 splash-resistant housing
Auto shutdown 1–60 min (or off)
Compact bench unit 242 × 195 × 68 mm, 900 g
GLP-compliant data management with date/time, slope and offset — audit-ready for QC labs
5-point calibration with auto-recognition handles NIST, GB and DIN buffer sets out of the box
Both USB (PC / flash) and RS-232 (printer) outputs — fits paper and paperless workflows
IP54 splash-resistant — robust against lab spills
5.7-inch LCD is large for the price band; readable from across the bench

Anwendungen

QC pH measurement for pharmaceutical raw materials, intermediates and finished products
pH measurement of buffers, electrolytes, infusions and dialysates
pH measurement in food, beverage, dairy and brewing labs
pH measurement in water and wastewater labs
pH measurement in cosmetic / chemical formulation labs
Educational and research pH measurement

Branchen

Pharmaceutical manufacturing — QC labs
Food and beverage labs
Cosmetics / personal care
Chemical / petrochemical
Water and environmental
Academic / research labs
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

GLP-compliant data management
IP54 ingress protection

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→