The SED-CILJ-A is an intelligent airborne dust particle counter for cleanroom monitoring. It samples 28.3 L/min (1 CFM) and reports six particle-size channels simultaneously (0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm). It auto-cl

GB/T 6167-2007JJF 1190-2008ISO 14644US Federal Standard 209EFDA 21 CFR Part 11
Lieferzeit
Auf Anfrage
Durchsatz
28.3 L/min

Funktionsweise

The sampling pump draws air at 28.3 L/min into the light-scattering sensor; a laser diode illuminates passing particles to produce scattered light, and a photodetector classifies particles into six size channels by pulse amplitude. The controller calculates results at 95% UCL confidence and auto-classifies cleanliness per ISO14644/FED209E. Data is stored internally and can be uploaded via WiFi/Bluetooth/USB drive or printed on the built-in thermal printer.

Prozessbeschreibung
1The sampling pump draws air at 28.3 L/min into the light-scattering sensor; a laser diode illuminates passing particles to produce scattered light, and a photodetector classifies particles into six size channels by pulse amplitude.
2The controller calculates results at 95% UCL confidence and auto-classifies cleanliness per ISO14644/FED209E.
3Data is stored internally and can be uploaded via WiFi/Bluetooth/USB drive or printed on the built-in thermal printer.

Technische Daten

Technische Daten für Variante: SED-CILJ-A

Technische Daten

Modell
SED-CILJ-A
Durchsatz
28.3 L/min
Spannung
220V 50Hz 1Φ
Versorgung
Power: 220 V, 50 Hz, single phase, 25 W. Built-in 220 Wh (16.8 V/15 Ah) Li-ion battery; 84 W (16.8 V/5 A) charger; charge time 3 h; designed working time 8 h.
Konformitätsangaben
Complies with GB/T6167-2007 (performance test method for dust particle counters) and JJF1190-2008 (calibration specification). Cleanliness classification per ISO14644, FED 209E and new-version GMP (dynamic/static). FDA 21 CFR Part 11 audit trail.
Leistung
0.025 kW

Wesentliche Merkmale

Six particle-size channels: 0.3 / 0.5 / 1.0 / 3.0 / 5.0 / 10.0 μm
Sampling flow 28.3 L/min (1 CFM)
Self-purge time ≤10 min
Particle-size distribution error ≤±30% at 0.5 μm and 5 μm
Particle concentration indication error ≤±30% at 0.5 μm
Concentration repeatability ≤±10%
Operating environment 15–35 °C, 10–85% RH
Sample period 1 s to 99 min, sample delay ≤99 s, measurement interval ≤999 s
Sampling modes: single, multi (up to 99), continuous
Cleanliness alarm: FED 209E Class 100–Class 300,000 / ISO 14644-1 Class 5–9
Imported semiconductor laser diode (>30,000 h life)
7-inch color touchscreen, Android 7.1 system
Built-in temperature, humidity, and barometric pressure sensors
21 CFR Part 11 audit trail (traceable, queryable, controllable)
WiFi / Bluetooth / USB drive data transfer
Built-in thermal printer with selectable channel printing
Built-in 220 Wh (16.8 V / 15 Ah) Li-ion battery, 6+ hour continuous sampling, 3 h charge; 84 W charger
Telescopic gimbal stand for flexible installation
Results convertible to particles/m³ and particles/ft³
Automatic cleanliness classification per ISO 14644 / FED 209E / GMP
Wireless data upload to monitoring platform for long-term cleanliness analytics
AC/DC dual operation with multi-hour battery for portable QC rounds
21 CFR Part 11-compliant audit trail for regulated industries

Anwendungen

Pharmaceutical cleanroom monitoring (factories, drug-testing labs, hospital ORs)
Semiconductor and precision-machining cleanrooms
Food hygiene cleanrooms (dairy, vacuum-sealed meat, condiments, agricultural products)
HEPA filter QC and efficiency testing
Optics / aerospace precision machining and test cleanrooms

Branchen

Pharmaceutical (GMP)
Hospital and healthcare
Semiconductor and electronics
Lebensmittel und Getränke
Filter manufacturing and QC
Optics and aerospace
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

GB/T 6167-2007
JJF 1190-2008
ISO 14644
US Federal Standard 209E
FDA 21 CFR Part 11

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→