SED-6S is a fully automatic 6-channel ultra-wide electronic tablet/capsule counting and bottling machine. Six imported counting sensors with six extra-wide guiding channels and a single discharge head feed through one he

GMP
Variante wählen (4)
Lieferzeit
Auf Anfrage
Durchsatz
20–40 Flaschen/min

Funktionsweise

Bottles are conveyed under the discharge head and held in fill position by a pneumatic stopper actuated when the bottle photo-eye detects a bottle (no-bottle-no-fill). Tablets/capsules are loaded into the 60 L hopper and travel down a vibratory feeder onto 6 wide guide channels, where 6 sets of dust-resistant photoelectric counting sensors automatically count each piece passing through. A turning-plate/flap sub-assembly discharges the counted dose smoothly into the bottle below. PLC + touch-screen logic tracks the count per bottle, stops on jam/no-bottle/fall-down faults, and triggers downstream conveyor advance.

Prozessbeschreibung
1Bottles are conveyed under the discharge head and held in fill position by a pneumatic stopper actuated when the bottle photo-eye detects a bottle (no-bottle-no-fill).
2Tablets/capsules are loaded into the 60 L hopper and travel down a vibratory feeder onto 6 wide guide channels, where 6 sets of dust-resistant photoelectric counting sensors automatically count each piece passing through.
3A turning-plate/flap sub-assembly discharges the counted dose smoothly into the bottle below.
4PLC + touch-screen logic tracks the count per bottle, stops on jam/no-bottle/fall-down faults, and triggers downstream conveyor advance.

Technische Daten

Technische Daten für Variante: SED-6S standard 6-channel ultra-wide counter (220V

Technische Daten

Modell
SED-6S
Durchsatz
20–40 Flaschen/min
Unterstützte Spannungen
220V 50Hz (voreingestellt); 110V 60Hz
Versorgung
Electrical: 220V / 50 Hz single phase, 0.6 kW. Compressed air: 0.6 MPa, 3.5 L/min, clean dry air. Single-point ground required.
Konformitätsangaben
Designed in line with GMP-style hygienic construction (stainless-steel contact parts, sealed dust-resistant photoelectric sensors). 12-month warranty from installation, max 16 months after delivery; lifetime maintenance.
Leistung
0.6 kW
Luftdruck
0.6Mpa

Abmessungen

Länge
1360 mm
Breite
1530 mm
Höhe
1700 mm
Gewicht
420 kg
Aufstellfläche
Single in-line counter+filler, approx 1360 mm L × 1530 mm W × 1700 mm H. In-feed and out-feed conveyors allow integration with downstream cappers/labellers.

Werkstoffe

Kontaktwerkstoffe
Stainless steel (food-contact path)
Gehäusewerkstoffe
Stainless steel frame and cover

Kompatibilität

Max. Bottle Diameter
100 mm
Min. Bottle Diameter
30 mm
Max. Bottle Height
180 mm
Min. Bottle Height
50 mm
Compatible Capsule Sizes
000-5#
Max. Pill Diameter
50 mm
Max. Plain Tablet Diameter
45 mm
Min. Plain Tablet Diameter
5.5 mm

Betrieb

Luftverbrauch
3.5 L/min

Physikalische Angaben

Channels
6 channels
Trichtervolumen
60 L

Wesentliche Merkmale

Six imported counting sensors with 6 extra-wide guiding channels and a single discharge head
Throughput 20–40 bottles/min depending on object size and pieces per bottle
Filling quantity adjustable 2–9999 pcs/bottle
60 L hopper volume
Bottle range: diameter 30–100 mm; height 50–180 mm
No mould change when switching counting objects — height adjusted by Easy-Adjust hand-wheel only
Anti-dust photoelectric sensor technology for stable counting in high-dust environments
Vibratory blanking + flap turning-plate sub-assembly for gentle, smooth discharge
No-bottle-no-fill detection (bottle photo-eye)
Touch-screen HMI with self-check / fault alarms
Conveyor speed adjustable via knob; PLC control with parameter storage
Compatible: pills ≤50 mm dia; capsules 000–5#; soft gelatin ≤50 mm dia; plain tablets 5.5–45 mm dia; special-shaped tablets; sugar-coated tablets; chewing gums
Wide compatibility: tablets, special-shaped tablets, sugar-coated tablets, capsules (000–5#), soft gelatin (transparent/opaque), pills and chewing gums all on one machine
Reduced changeover time — no mould swap, just hand-wheel height adjustment
Counting error below national standard for bottle filling
High intelligence: no-bottle-no-count, self-check, fault alarms
Operator-friendly: simple training, tool-free disassembly for cleaning
Suitable for stand-alone use or integration into a complete bottling line

Anwendungen

Counting and bottling of tablets, capsules, soft gelatin, pills, chewing gums
Pharmaceutical and nutraceutical bottling lines
Counting of granular solids in food/hardware/stationery industries (e.g. candies, nuts, frozen foods, seeds, screws)

Branchen

Pharmaceutical / medicine
Nutraceutical / health products
Hospital pharmacy preparation rooms
Confectionery and food
Hardware fasteners
Toys / building blocks

Komponentenhersteller

Bottle Detection Photoelectric Sensor
Germany SICK
Main Control System
Shengde Machinery
Switching Power Supply
Mean Well
Lift Motor
MAILI
Counting Photoelectric Sensor
Shengde Machinery
Pneumatic Components
AirTAC
Conveyor Motor
MAILI
Operation Panel / HMI
Delta
Miniature Circuit Breaker (MCB)
Schneider
Emergency Stop Switch
Schneider
Bottle Blockage / Tilting Detection Sensor
Germany SICK
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

GMP

Reinigung und Wartung

Tool-less disassembly of vibration plates and flap sub-assembly for cleaning. Wipe stainless-steel contact path with neutral detergent. Empty hopper between products; brush photoelectric sensor windows with soft brush to clear dust. Clean before and after each production shift.

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→