Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
SED-2500RZGF-Q
Auf Anfrage
SED-2500RZGF-Q
SED · SED-2500RZGF-Q · Hervorgehoben

SED-2500RZGF-Q — Non-PVC Soft Bag Form-Fill-Seal Machine

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-2500RZGF-Q automatic non-PVC soft bag form-fill-seal (FFS) line for pharmaceutical infusion bags. Forms two bags per cycle, each with two SFC ports. Compatible with 50–1000 ml non-PVC infusion soft bags. Rated output

GMP compliant designFDA-compliant materials
Variante wählen (2)
Lieferzeit
Auf Anfrage
Durchsatz
1800–2500 Stück/h

Funktionsweise

Single-track linear FFS system with motor-driven film transfer via pneumatic grippers. Film passes through twelve stations: (01) motor-controlled unwinding with castoring wheel buffer; (02) hot-foil printing with ±0.5 °C precision; (03) film transfer with film opener for port insertion; (04) contour welding and cutting with port pre-adhesion (±0.5 °C control); (05) port pre-heating; (06) port feeding via feeder bowl and buffer; (07) port welding (±0.5 °C control); (08) waste-edge ejection; (09) bag flip and leak detection (empty bags checked by vacuum — leaking or absent bags bypass filling); (10) two filling systems with Endress+Hauser mass flow metering (±1.0% accuracy, max fill temp 85 °C); (11) cap station with feeder bowl, vacuum pick, and welding; (12) bag outfeed via conveyor belt. Bus-based industrial network simplifies wiring.

Prozessbeschreibung
1Single-track linear FFS system with motor-driven film transfer via pneumatic grippers.
2Film passes through twelve stations: (01) motor-controlled unwinding with castoring wheel buffer; (02) hot-foil printing with ±0.5 °C precision; (03) film transfer with film opener for port insertion; (04) contour welding and cutting with port pre-adhesion (±0.5 °C control); (05) port pre-heating; (06) port feeding via feeder bowl and buffer; (07) port welding (±0.5 °C control); (08) waste-edge ejection; (09) bag flip and leak detection (empty bags checked by vacuum — leaking or absent bags bypass filling); (10) two filling systems with Endress+Hauser mass flow metering (±1.0% accuracy, max fill temp 85 °C); (11) cap station with feeder bowl, vacuum pick, and welding; (12) bag outfeed via conveyor belt.
3Bus-based industrial network simplifies wiring.

Technische Daten

Technische Daten für Variante: SED-2500RZGF-Q (~1800 L/min compressed air)

Technische Daten

Modell
SED-2500RZGF-Q
Durchsatz
1800–2500 Stück/h
Spannung
3 Phase 380V 50Hz
Versorgung
3-phase 380V 50Hz electrical (max 10 kW); compressed air 0.5–0.75 MPa dry oil-free at ~1800 L/min (SED-2500RZGF-Q variant) or ~1000 L/min (SED-2500RZGF-Q1 variant); filling pressure 0.3–0.45 MPa; optional cooling water; optional nitrogen; recommended room conditions 20–24 °C, 45–65% RH (max 85% RH)
Konformitätsangaben
Designed for pharmaceutical use according to GMP and FDA guidelines. All product-contact components use AISI 316L stainless steel, mold steel, and silicone rubber meeting FDA and GMP standards.
Leistung
10 kW
Luftdruck
Compressed air 0.5-0.75 MPa, dry oil-free; consumption ~1800 L/min (1000 L/min for SED-2500RZGF-Q1 variant); filling pressure 0.3-0.45 MPa

Abmessungen

Länge
4350 mm
Breite
1900 mm
Höhe
1800 mm
Aufstellfläche
4350 mm (L, including film roll) × 1900 mm (W, including protective enclosure) × 1800 mm (H, including protective enclosure)

Werkstoffe

Kontaktwerkstoffe
AISI 316L Edelstahl; mold steel; silicone rubber (FDA/GMP compliant)
Gehäusewerkstoffe
AISI 304L stainless steel framework; polycarbonate safety doors and windows

Wesentliche Merkmale

Precise temperature control within ±0.5 °C ensures compatibility with all qualified non-PVC film materials
Zero-tolerance manufacturing: mold flatness/parallelism within 1/100 mm for tool-free exchange
Advanced industrial network (bus system) connecting valve terminals and limit switches — reduces wiring and maintenance errors
Leak detection at station 09: leaking or absent bags are automatically skipped at filling
Unique mold-and-heating-plate separation design for extremely fast mold change without special tools
In-line sterilisation (CIP/SIP) up to 125 °C available as option
Min. 99.97% pass rate based on qualified materials and correct operation
Waste-edge rejection rate 99.99% with independent waste collection tray
Noise ≤75 dB
GMP and FDA compliant design
High productivity: 2500 bags/h (50 ml) on compact 4350×1900×1800 mm footprint
One permanent operator; second operator only during film change
Fully integrated 12-station continuous FFS — no intermediate handling
Optional CIP/SIP in-line cleaning and steam sterilisation at 125 °C
Compatible with 50–1000 ml bags; adding new size only requires purchasing additional molds
Omron control platform (PLC, HMI, servo, temperature); Festo pneumatics; E+H flow meters

Anwendungen

Pharmaceutical infusion soft bag form-fill-seal for non-PVC bags 50–1000 ml
Two-bag per cycle FFS production
Bags with two SFC ports per bag

Branchen

Pharmaceutical injectable / infusion manufacturing

Komponentenhersteller

Control system / PLC / HMI / servo / temperature control
Omron
Pneumatic system (cylinders, valve islands, service units)
Festo
Mass flow meter (filling accuracy control)
Endress+Hauser (E+H)
Pressurized oil-air cylinder
TOX
Sensors
IMF
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

GMP compliant design
FDA-compliant materials

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→