SED-240JNC-L Desktop Capsule/Tablet Weight Sampling Machine. 4 weighing channels with CMC-0.1 high-precision strain-gauge load cells designed by SED. Weighs samples at 350 caps/min (21,000/hour) at user-defined intervals

21CFR Part 11cGMPData integrity
Lieferzeit
Auf Anfrage
Durchsatz
350 capsules/hour (350 caps/min)

Funktionsweise

The operator loads sample capsules or tablets into the input chute. Pneumatic cylinders release one capsule at a time into each of the 4 weighing channels, each equipped with a CMC-0.1 high-precision load cell. The SED CL-12 data acquisition controller reads the load cell output with military-aviation-grade zero tracking and dynamic compensation algorithms to suppress ground vibration and airflow interference. Each capsule weight is recorded; real-time statistics (mean, sigma, control chart, full-batch normal distribution) are computed. Out-of-range capsules are rejected by AirTAC sorting cylinders (MPE8×10). Calibration weight is automatically placed by an AirTAC calibration cylinder (HLH6×25) to re-zero and calibrate the cells. The SPT SP-D10 microneedle printer prints a sampling label at each interval.

Prozessbeschreibung
1The operator loads sample capsules or tablets into the input chute.
2Pneumatic cylinders release one capsule at a time into each of the 4 weighing channels, each equipped with a CMC-0.1 high-precision load cell.
3The SED CL-12 data acquisition controller reads the load cell output with military-aviation-grade zero tracking and dynamic compensation algorithms to suppress ground vibration and airflow interference.
4Each capsule weight is recorded; real-time statistics (mean, sigma, control chart, full-batch normal distribution) are computed.
5Out-of-range capsules are rejected by AirTAC sorting cylinders (MPE8×10).
6Calibration weight is automatically placed by an AirTAC calibration cylinder (HLH6×25) to re-zero and calibrate the cells.
7The SPT SP-D10 microneedle printer prints a sampling label at each interval.

Technische Daten

Technische Daten für Variante: SED-240JNC-L

Technische Daten

Modell
SED-240JNC-L
Durchsatz
350 capsules/hour (350 caps/min)
Spannung
AC 220V/50Hz (control DC 24V)
Leistung
0.6 kW
Luftdruck
0.4-0.6 MPa, 0.01 m³/min

Abmessungen

Länge
520 mm
Breite
300 mm
Höhe
550 mm
Gewicht
38 kg

Wesentliche Merkmale

Desktop design — compact 520×300×550 mm, 38 kg
4 weighing channels with SED CMC-0.1 high-precision load cells
Speed 350 caps/min (21,000/hour)
Weighing range 10–2000 mg; accuracy ±2.0 mg; scale interval 0.1 mg
Capsule size 000#–5# (3 mold sets); round tablets <15 mm diameter (custom mold)
Built-in calibration weight — automatic calibration and zeroing
Military-aviation-grade zero tracking + dynamic compensation
Stable weighing under ground vibration and airflow interference
Programmable sampling interval with audible alarm reminder
Real-time grain-weight control chart + full-batch normal distribution
Auto-rejection of out-of-spec capsules/tablets
Separate conforming/nonconforming product bins
21CFR Part 11 compliant — electronic signatures and records, data integrity
Siemens S7-200 SMART PLC + SED CL-12 controller + SED 10.4″ HMI
Wi-Fi + Ethernet + USB + COM for remote monitoring and SCADA
SPT SP-D10 microneedle printer for label output
Expandable: SMC module can increase to a maximum of 4 channels as a small capsule checkweigher
21CFR Part 11 + cGMP compliance — global pharma audit-ready
SED in-house load cells, controller, and software — low replacement and maintenance cost
Far exceeds manual sampling effectiveness — eliminates personnel error
Frees operator from per-grain electronic balance weighing
24-hour continuous frequent sampling capability
Wi-Fi + Ethernet for remote monitoring and Internet data exchange

Anwendungen

Capsule weight sampling and monitoring at capsule filling machines
Tablet weight sampling and monitoring
Empty capsule weight pre-inspection (4-channel mode)
GMP / 21CFR Part 11 audited in-process weight QC

Branchen

Pharmaceutical (capsule and tablet manufacturing)
Nutraceutical / dietary supplement

Komponentenhersteller

Weigh cell CMC-0.1 ×4
SED (in-house design)
Data acquisition controller CL-12
SED (in-house design)
HMI 10.4" touch screen
SED (in-house design)
PLC S7-200 SMART
Siemens
Electromagnetic valves SY3120 ×6
SMC
Air source treatment AW30/AFM30
SMC
Releasing cylinder CDU10×40S
SMC
CAM bearing CFFAM3-6 ×2
IKO
Linear bearing LM6UU ×4
YTP
Power supply RS-100-24
MEAN WELL
Power supply RS-100-5
MEAN WELL
Sorting cylinder MPE8×10 ×4
AirTAC
Calibrating cylinder HLH6×25
AirTAC
Guide rail LRM5BK-L-H-A
AirTAC
Microneedle printer SP-D10
SPT
Permutation motor Z32B0-40S
ZHONGDA
Aviation-grade power supply 12V1A
Ainuo
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

21CFR Part 11
cGMP
Data integrity

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→