Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Temperiertes Heizsystem mit Kühlung / Cooling & Heating Temperature Control System
SED-15LR-X
Auf Anfrage
SED-15LR-X
SED · SED-15LR-X · Hervorgehoben

SED-15LR-X — Cooling & Heating Temperature Control System

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-15LR-X cooling & heating temperature control system for reactor jackets and other process vessels. Single closed circulating heat-transfer-medium loop driven by a circulating pump (max 110 L/min @ 2.5 bar) through a

Lieferzeit
Auf Anfrage
Durchsatz
110 L/min

Funktionsweise

Liquid refrigerant in the evaporator absorbs heat from the circulating heat-transfer oil in a plate heat exchanger, evaporating from liquid to gas. The compressor draws in this vapor, compresses it to high temperature and pressure, and passes it through an oil separator to remove entrained refrigerating oil. The high-pressure gas then enters the condenser, where it rejects heat to ambient air or cooling water and condenses to high-pressure room-temperature liquid. This liquid passes through a drying filter and an expansion valve, dropping in pressure and temperature to become low-pressure liquid. The low-pressure liquid enters the evaporator to complete the cycle. The cooled (or heated) heat-transfer oil is circulated by pump through the customer's reactor jacket to drive material temperature to setpoint. Compared with dual- or triple-compressor cascade systems, the single-compressor design ensures reliable refrigeration at high temperature with simpler components and lower failure rates, while also benefiting the compressor lubrication oil system and extending service life.

Prozessbeschreibung
1Liquid refrigerant in the evaporator absorbs heat from the circulating heat-transfer oil in a plate heat exchanger, evaporating from liquid to gas.
2The compressor draws in this vapor, compresses it to high temperature and pressure, and passes it through an oil separator to remove entrained refrigerating oil.
3The high-pressure gas then enters the condenser, where it rejects heat to ambient air or cooling water and condenses to high-pressure room-temperature liquid.
4This liquid passes through a drying filter and an expansion valve, dropping in pressure and temperature to become low-pressure liquid.
5The low-pressure liquid enters the evaporator to complete the cycle.
6The cooled (or heated) heat-transfer oil is circulated by pump through the customer's reactor jacket to drive material temperature to setpoint.
7Compared with dual- or triple-compressor cascade systems, the single-compressor design ensures reliable refrigeration at high temperature with simpler components and lower failure rates, while also benefiting the compressor lubrication oil system and extending service life.

Technische Daten

Technische Daten für Variante: SED-15LR-X

Technische Daten

Modell
SED-15LR-X
Durchsatz
110 L/min
Spannung
AC 220V/60Hz, 26 kW max (operating ~21 kW max)
Versorgung
AC 220V / 60Hz @ 26 kW max (operating 21 kW max); cooling water 4000 L/h @ 20 ℃, 1.5-4 bar; flat level installation surface.
Konformitätsangaben
Closed-loop fully sealed system; multi-level safety protections (HP switch, overload relay, thermal protection, refrigerator overload).
Leistung
26 kW
Luftdruck
Circulating-medium 2.5 bar (pump), cooling water 1.5-4 bar

Abmessungen

Länge
800 mm
Breite
1200 mm
Höhe
1850 mm
Gewicht
380 kg
Aufstellfläche
800 × 1200 × 1850 mm; require ≥75 cm clearance around equipment for ventilation and maintenance; placement must be flat and level; altitude below 1000 m.

Werkstoffe

Kontaktwerkstoffe
SUS 304 (outer cover); 316L touched only by external sensor wells
Gehäusewerkstoffe
SUS 304

Wesentliche Merkmale

Wide -60 to +250 ℃ temperature range, continuous closed loop
Single-compressor refrigeration (simpler, more reliable than cascade)
R404A / R23 mixed refrigerant
Heating 15 kW; cooling 15 kW @ 250 ℃, 2.8 kW @ -55 ℃
Material temperature control accuracy ±1 ℃
Optional jacket vs material temperature differential control
Feedforward PID + model-free self-tree-building algorithm
5 programs × 25 steps; MODBUS RTU / RS-485
7" color HMI with curve display & recording
Three-point temperature feedback (inlet / outlet / external reactor)
Closed expansion vessel (no medium replacement, low oxidation/moisture)
High-efficiency plate heat exchanger reduces fluid demand
Self-diagnosis + multi-level safety protections
SUS304 outer cover
Single compressor reliability — simpler structure, lower failure rate vs cascade
No heat-transfer medium replacement needed across full -60 to 250 ℃
No oil mist at high temperature, no moisture pickup at low temperature
European-brand refrigeration components (Dorin, Carlyle, Copeland, Danfoss, Emerson)
12-month warranty (extendable to 36 months for +10% price)
12-hr written response, on-site within 24-72 hr
MODBUS RTU integration into customer DCS

Anwendungen

Reactor jacket temperature control
Pharmaceutical / fine chemical process temperature control
Crystallization process temperature control
API synthesis precise thermal management

Branchen

Pharmaceutical (API)
Fine chemical
Biotechnologie
Lab / pilot R&D

Komponentenhersteller

Compressor: DORIN (Italy) / Carlyle / Copeland
Drying filter: Danfoss
Oil separator: Emerson
Expansion valve: Danfoss / Emerson Thermal Expansion Valve
Evaporator: Danfoss / High Force plate heat exchanger
Refrigerant: R404A / R23 mixed
Refrigeration system pressure gauge: (Jindian)
Electrical parts: Schneider
Touch screen: 7" color (customized)
Phase-sequence/phase-failure protector: (Kesi)
Solid-state relay: (Kangyu)
PLC + modules: Wuxi
Expansion system: Wuxi
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→