Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Reinstwasseranlage / Laboratory Ultrapure Water System
SED-15CCS-Q
Auf Anfrage
SED-15CCS-Q
SED · SED-15CCS-Q · Hervorgehoben

SED-15CCS-Q — Laboratory Ultrapure Water System

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

Laboratory ultrapure water system (SED-15CCS-Q), 10-15 L/h, produces water meeting Grade II laboratory standard. Inlet: municipal tap water. Dual outlets: drinkable purified water and ultrapure water (resistivity ≥15 MΩ·

Output meets Grade II laboratory water standard
Lieferzeit
Auf Anfrage
Durchsatz
10–15 L/h

Funktionsweise

Tap water → precision sediment + activated carbon pre-treatment removes particles, chlorine, organics → booster pump (0-0.9 MPa) → reverse osmosis (RO) demineralizes water (pressure drives H2O through membrane while ions/organics/colloids are rejected and discharged as concentrate) → polishing mixed-bed (UK Purolite resin) raises resistivity to ≥15 MΩ·cm → 0.2μm terminal microfilter removes residual particles, pyrogens, and bacteria. Anti-scaling RO program periodically flushes the membrane.

Prozessbeschreibung
1Tap water → precision sediment + activated carbon pre-treatment removes particles, chlorine, organics → booster pump (0-0.9 MPa) → reverse osmosis (RO) demineralizes water (pressure drives H2O through membrane while ions/organics/colloids are rejected and discharged as concentrate) → polishing mixed-bed (UK Purolite resin) raises resistivity to ≥15 MΩ·cm → 0.2μm terminal microfilter removes residual particles, pyrogens, and bacteria.
2Anti-scaling RO program periodically flushes the membrane.

Technische Daten

Technische Daten für Variante: SED-15CCS-Q

Technische Daten

Modell
SED-15CCS-Q
Durchsatz
10–15 L/h
Spannung
220V
Versorgung
Inlet: municipal tap water, TDS conductivity <200 μS/cm, pressure >0.1 MPa, temperature 5-40°C. Power: 220V, 50W. Drain for RO concentrate.
Konformitätsangaben
Outlet ultrapure water: conductivity ≤0.07 μS/cm, resistivity 15 MΩ·cm. Suitable for hemodialysis, IV preparation, and other pharmaceutical-grade applications.
Leistung
0.05 kW

Abmessungen

Länge
610 mm
Breite
485 mm
Höhe
713 mm
Gewicht
26 kg
Aufstellfläche
61 × 48.5 × 71.3 cm bench-top, 26 kg

Werkstoffe

Kontaktwerkstoffe
Food-grade PE tubing; SS pressure gauges; quick-connect plastic fittings
Gehäusewerkstoffe
Standard cabinet (not specified)

Wesentliche Merkmale

Output 10-15 L/h
Dual outlet: pure water (drinkable) + ultrapure water (≥15 MΩ·cm)
Six-stage purification with quick-connect cartridges
Built-in online resistivity meter (Keda brand)
Online pressure display (2× SS pressure gauges, 0-7 MPa)
Automatic RO membrane flushing on startup, anti-scaling program
Low/high pressure auto-shutoff and system interlock protection
Water-low / water-full auto stop
Booster pump 0-0.9 MPa pressure range
Microcomputer control panel
Compact bench-top: 610×485×713 mm, 26 kg, 50 W
Output 40× higher than comparable imported lab products at 1/50 the operating cost
Original-water utilization 60-80% when feed <250 μS/cm, hardness ≤100 ppm
Quick-connect components for easy validation, calibration, maintenance, cleaning, sanitization, sampling
CSM anti-fouling RO membrane
UK Purolite polishing resin for high resistivity
Compact bench-top: 61×48.5×71.3 cm, only 26 kg, 50W

Anwendungen

Electronics: monocrystalline silicon, semiconductor, IC chip packaging, displays, PCB
Pharmaceutical: large infusion (LVP), formulations, hemodialysis water
Coating: electroplating, battery, electrophoretic paint
Chemical industry: pharmaceuticals, dyeing, fine chemicals, cosmetics
Lab use: factory/university/company production labs, chemistry/physics labs, pilot plants, hospital biochemistry
Analysis & testing

Branchen

Pharma
Electronics
Healthcare / hospital lab
Chemical / fine chemical
University / research lab
Coating / surface treatment

Komponentenhersteller

CSM — RO membrane (anti-fouling,100G)
Purolite UK — polishing resin
Keda — online resistivity meter
Domestic — booster pump, solenoid valve, control panel
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

Output meets Grade II laboratory water standard

Reinigung und Wartung

Periodic consumable replacement: 1μm PP cartridge every 1-3 months; activated carbon every 3-6 months; ultrapure cartridges every ~1000-2000L; terminal microfilter every 3-12 months; RO membrane every 1-2 years. If idle >1 month, soak in disinfectant or run periodically.

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→