صالة عرض في أونتاريو، كاليفورنيا · استفسر عن الدعم في وجهتك
الرئيسية / المعدات / مكنسة شفط / Explosion-Proof Industrial Vacuum Cleaner
SED-3XCQ-Y
حسب الطلب
SED-3XCQ-Y
SED · SED-3XCQ-Y · 1 وحدة مباعة

SED-3XCQ-Y — Explosion-Proof Industrial Vacuum Cleaner

لا تزال ترجمة الوصف الكامل لهذا الطراز قيد العمل. راجع التفاصيل بالإنجليزية أو اطلب المعلومات من فريقنا. English

SED-3XCQ-Y explosion-proof industrial vacuum cleaner for primary explosion-proof work areas (Zone 21 dust-explosion-proof environments). Stainless steel body with explosion-proof motor, explosion-proof switch, anti-stati

ISO9001CEEX tD A21 IP65 T130°C
مدة التسليم
حسب الطلب
الطاقة الإنتاجية
تواصل معنا

مبدأ العمل

High-voltage immediate-discharge explosion-proof vacuum motor generates suction. Air flows through the inlet hose and cyclone separator, then through the anti-static coated filter element(1 micron) before exiting. Static is dissipated via grounded static cables/clamps and anti-static filter. Explosion-relief diaphragm opens to release pressure if explosive concentration is reached in the drum. Manual blowback(aerodynamic) cleans dust off the filter without stopping the machine.

وصف سير العمل
1High-voltage immediate-discharge explosion-proof vacuum motor generates suction.
2Air flows through the inlet hose and cyclone separator, then through the anti-static coated filter element(1 micron) before exiting.
3Static is dissipated via grounded static cables/clamps and anti-static filter.
4Explosion-relief diaphragm opens to release pressure if explosive concentration is reached in the drum.
5Manual blowback(aerodynamic) cleans dust off the filter without stopping the machine.

المواصفات الفنية

مواصفات التكوين: SED-3XCQ-Y

المواصفات

الطراز
SED-3XCQ-Y
الجهد
380V/50Hzثلاثي الطور
تفاصيل المطابقة
ISO9001 quality certified; EU CE export certified; explosion-proof rating Ex tD A21 IP65 T130°C; IP65 ingress protection; complies with 2003 electrical standards and 73/23/EEC electrical directive; all electrical components EX certified.
القدرة
3 kW
ضغط الهواء
26 kPa vacuum suction

الأبعاد

الطول
1250 mm
العرض
680 mm
الارتفاع
1430 mm
الوزن
95 kg

المواد

مواد التلامس
فولاذ مقاوم للصدأ (drum and body)
مواد الهيكل
فولاذ مقاوم للصدأ

الخصائص الرئيسية

Primary explosion-proof rated; suitable for Dust Explosion Zone 21
Explosion-proof rating Ex tD A21 IP65 T130°C; ingress protection IP65
Explosion-proof motor and explosion-proof switch(EX certified electrical components)
Explosion-relief diaphragm releases pressure if explosive limit reached in drum
Anti-static coated filter element(1 micron filtration; up to 52,800 cm² filter area)
Anti-static cables/clamps and anti-static flame-retardant hose
Cyclone separator reduces dust entering filter chamber
Bundled water filtration tank for flammable/explosive dust collection
Phase-loss, overheat, and overload protection switch
Vacuum pressure gauge for real-time filter monitoring
Manual blowback for filter self-cleaning during operation
Pressure relief valve continues motor cooling and prevents overheating
Upper/lower drum separation with wheels for safe material handling
100 L stainless steel dust collection drum
True primary explosion-proof rating(Ex tD A21 IP65 T130°C) for Zone 21 dusts
ISO9001 quality certified; EU CE export certified
Continuous-duty explosion-proof motor
Bundled water filtration tank for flammable/explosive substances
1 micron anti-static filtration
Suction force: 26 kPa airflow; 380 m³/h capacity
Customizable per customer requirements

التطبيقات

Collection of flammable/explosive powders and dusts
Dust collection in Zone 21 explosive dust environments
Spark-containing or high-temperature dust collection
Sticky/oily fume capture
Grinding and polishing industries
Metal processing and casting industries

القطاعات

Pharmaceutical (explosive powder handling)
Chemical
Metal processing
Foundry/Casting
Grinding and polishing
SED
تواصل مع SED Sales Team
متخصصو المعدات · تواصل عبر واتساب
استفسر عن مواعيد العمل وتوفر الفريق

الامتثال

ISO9001
CE
EX tD A21 IP65 T130°C

التنظيف والصيانة

Periodically clean inlet/outlet filter and silencer per usage. Clean residue from filter via manual blowback. Replace filter when negative-pressure gauge stays in red zone after cleaning. Empty dust drum into waste/recycling per local regulations. Always disconnect power before maintenance. Lubricate motor bearings periodically. Do not use flammable solvents(gasoline, benzene, alcohol) to clean the machine.

الوثائق

ورقة البيانات (PDF)
نظرة عامة على المعدات والمواصفات والأبعاد · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
دليل التشغيل
التركيب والتشغيل واستكشاف الأعطال · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
ورقة مقارنة (قياسي واقتصادي)
مقارنة التكوينات · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
بروتوكولات IQ / OQ / PQ
وثائق التحقق لمطابقة GMP · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
بروتوكولات FAT / SAT
اختبارات القبول في المصنع وفي الموقع · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
رسومات CAD (STEP / IGES / DWG)
رسومات هندسية لتخطيط المنشأة · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
شهادات المعايرة
مستوى الصوت ومقاومة التأريض والعزل وخشونة السطح · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
DQ (تأهيل التصميم)
بروتوكول كامل لتأهيل التصميم · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
شهادات المواد
تركيب الفولاذ المقاوم للصدأ 316L · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
SED
واتساب · مبيعات SED