Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Enceinte à température et humidité constantes / Programmable Constant Temperature and Humidity Test Chamber
SED-50HWX-A
Sur devis
SED-50HWX-A
SED · SED-50HWX-A · En vedette

SED-50HWX-A — Programmable Constant Temperature and Humidity Test Chamber

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-50HWX-A Programmable Constant Temperature and Humidity Test Chamber. Provides constant or alternating high/low temperature and humidity test environments for heat, cold, dryness, and humidity resistance testing in el

GB5170.2/3/5/6-95GB/T2423.2-89 (IEC68-2-2) - high temperatureGB/T2423.3-93 (IEC68-2-3) - constant damp heatGB/T2423.4-93 (IEC68-2-30) - alternating damp heat
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Internal recirculating airflow: fan draws workspace air into a duct cavity at one end where heater, refrigerant evaporator, and humidifier/dehumidifier condition it; conditioned air blows back out, exchanges heat with the test specimen, and is re-drawn through the duct, cycling repeatedly to reach setpoint temperature and humidity. PID-controlled heater via AC contactor; Pt100 platinum RTDs for temperature; Pt100 wet/dry bulb for humidity; TEMI880 PLC touchscreen controller. Servo refrigerant flow control saves 30 percent or more energy.

Processus de fonctionnement
1Internal recirculating airflow: fan draws workspace air into a duct cavity at one end where heater, refrigerant evaporator, and humidifier/dehumidifier condition it; conditioned air blows back out, exchanges heat with the test specimen, and is re-drawn through the duct, cycling repeatedly to reach setpoint temperature and humidity.
2PID-controlled heater via AC contactor; Pt100 platinum RTDs for temperature; Pt100 wet/dry bulb for humidity; TEMI880 PLC touchscreen controller.
3Servo refrigerant flow control saves 30 percent or more energy.

Caractéristiques techniques

Caractéristiques de la variante : SED-50HWX-A

Caractéristiques

Modèle
SED-50HWX-A
Tension
220V/50Hz
Puissance
3 kW

Dimensions

Longueur
870 mm
Largeur
550 mm
Hauteur
1400 mm

Matériaux

Matériaux en contact
SUS304 brushed stainless steel (inner chamber)
Matériaux du bâti
SUS304 brushed stainless steel (inner); SUS satin stainless steel (outer); high-temp/cold silicone seal (red door gasket); pure aluminum fin evaporator; copper tube + aluminum fin condenser

Caractéristiques principales

Inner chamber 350x350x400 mm (DxWxH)
Outer chamber approx. 870x550x1400 mm (DxWxH)
Temperature range 0-150 C, resolution 0.01 C
Humidity range 20-98% RH, resolution 0.1% RH
Temperature fluctuation +/-0.5 C, uniformity +/-2 C
Heating rate 2-4 C/min, cooling rate 0.7-1 C/min (no-load, non-linear)
Humidity fluctuation +/-2% RH, deviation +/-2%
TEMI880 color touchscreen PLC controller (Korean Samwon)
Permanent historical data save, resume after power loss
Reservation power on/off; auto post-test return to ambient (anti-condensation/frost)
Servo refrigerant flow control saves 30%+ energy
Pure aluminum fin evaporator
Inner box: SUS304 brushed stainless steel; outer box: SUS satin stainless steel
Lead-through hole 50 mm diameter
Stainless-steel finned heater tubes (2.5-4x heat dissipation vs plain tubes)
Tecumseh-type compressor (higher COP than piston type, low noise)
Power: 3 kW at AC 220V/50Hz
Permanent history retention with data curve save on power loss
Auto return to ambient after test to prevent condensation and frost
Energy-saving servo refrigerant flow control (30%+ saving)
Compliant with GB5170 and IEC68-2 environmental test standards

Applications

Constant temperature/humidity testing
Alternating high/low temperature/humidity testing
Heat, cold, dryness, humidity resistance testing of materials and components

Secteurs

Electronics
Alimentation électrique
Communications
Instruments
Automotive
Plastics
Metals
Food
Chemical
Building materials
Medical
Aerospace

Marques des composants

PLC touchscreen controller TEMI880
Samwon (Korea)
Compressor
Tecumseh
AC contactor/thermal overload
Schneider
Small relay
Omron
Circuit breaker
Delixi
Water-level float switch
Wanfanyi
Pump (100 gallon)
Dengyuan (Taiwan)
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

GB5170.2/3/5/6-95
GB/T2423.2-89 (IEC68-2-2) - high temperature
GB/T2423.3-93 (IEC68-2-3) - constant damp heat
GB/T2423.4-93 (IEC68-2-30) - alternating damp heat

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→