Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Congélateur vertical / 400L Vertical Low-Temperature Test Cabinet (Programmable High/Low Temperature Test Box)
SED-400LSLG-X
Sur devis
SED-400LSLG-X
SED · SED-400LSLG-X · En vedette

SED-400LSLG-X — 400L Vertical Low-Temperature Test Cabinet

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-400LSLG-X 400 L Vertical Low-Temperature Test Cabinet (Programmable High/Low Temperature Test Box). Internal volume 400 L (500 × 600 × 1300 mm). External dimensions approximately 760 × 870 × 1980 mm. Net weight 190 k

ISO 9001 quality management systemGB10586-89GB10592-89GB/T2423.2-93 (equivalent to IEC 68-2-3)
Choisir une variante (10)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Single-stage refrigeration cycle using a fully enclosed compressor unit with R404A refrigerant. A multi-section fin-type evaporator cools the chamber. PT100 RTD dry-bulb temperature sensor provides feedback to the computer controller, which regulates the compressor to maintain set temperature. The hot-air distributor/fan ensures temperature uniformity within the chamber (≤±3 °C fluctuation, ≤±3 °C uniformity). No automatic defrost — user must periodically power off for natural defrost.

Processus de fonctionnement
1Single-stage refrigeration cycle using a fully enclosed compressor unit with R404A refrigerant.
2A multi-section fin-type evaporator cools the chamber.
3PT100 RTD dry-bulb temperature sensor provides feedback to the computer controller, which regulates the compressor to maintain set temperature.
4The hot-air distributor/fan ensures temperature uniformity within the chamber (≤±3 °C fluctuation, ≤±3 °C uniformity).
5No automatic defrost — user must periodically power off for natural defrost.

Caractéristiques techniques

Caractéristiques de la variante : 30 L: 540×585×770 mm (outer)

Caractéristiques

Modèle
SED-400LSLG-X
Tension
Single-phase AC 220V, 50Hz (allowable 220-240V, 49-51 Hz)
Fluides et énergie
Single-phase AC 220 V / 50 Hz (allowable 220–240 V, 49–51 Hz); approximately 350 W; dedicated outlet with reliable earth required
Détails de conformité
Complies with GB10586-89, GB10592-89, GB/T2423.2-93 (equivalent IEC 68-2-3). ISO 9001 quality system. Overvoltage class: Class I. Refrigerant: R404A. Climate type: Temperate (N).
Puissance
0.35 kW

Dimensions

Longueur
760 mm
Largeur
870 mm
Hauteur
1980 mm
Poids
190 kg
Emprise au sol
760 mm (L) × 870 mm (W) × 1980 mm (H)

Matériaux

Matériaux en contact
Stainless steel inner liner
Matériaux du bâti
Outer shell: cold-rolled steel 1.2 mm with baked-on coating; inner liner: stainless steel; insulation: polyurethane foam

Caractéristiques principales

Internal volume 400 L (500 × 600 × 1300 mm interior)
External dimensions approximately 760 × 870 × 1980 mm
Net weight 190 kg
Power 350 W
Temperature range −15 °C to +45 °C, adjustable
Temperature fluctuation ≤ ±3 °C
Temperature uniformity ≤ ±3 °C
Single-stage refrigeration with fully enclosed compressor (R404A)
Polyurethane integral foam insulation
Stainless steel inner liner — easy to clean
Computer temperature controller, digital display
Noise ≤ 50 dB(A)
Environment: 5–35 °C ambient, ≤75% RH
Stainless steel inner liner — easy to clean and aesthetically clean
Quick cool-down via single-stage refrigeration
Polyurethane foam insulation for strong thermal retention
ISO 9001 quality management system
1-year warranty; 24-hour response, 48-hour onsite service
Available in a range of capacities from 30 L to 938 L
Complies with GB10586-89, GB10592-89, GB/T2423.2-93 (≡ IEC 68-2-3)

Applications

Low-temperature stability testing of pharmaceuticals
Pharmaceutical sample and reagent cold storage
Cold chain testing for medicines and biologicals
Low-temperature performance testing of materials and electronics
Laboratory cold storage requiring controlled temperature

Secteurs

Pharmaceutical R&D and QC
Biological samples / vaccines
Electronics testing
Materials science laboratories
Medical and clinical laboratories
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

ISO 9001 quality management system
GB10586-89
GB10592-89
GB/T2423.2-93 (equivalent to IEC 68-2-3)

Nettoyage et entretien

No automatic defrost function. After a period of use, power off and allow natural defrost. Failure to defrost periodically will reduce cooling performance. Do not allow water into the electrical control box or electrical components during cleaning.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→