Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
SED-18ZQ-J
Sur devis
SED-18ZQ-J
SED · SED-18ZQ-J · En vedette

SED-18ZQ-J — Clean-Type Electric Steam Generator

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-18ZQ-J is an 18 kW clean-type electric steam generator (304 stainless steel series). Rated steam output 25 kg/h; saturated steam temperature 171°C; rated steam pressure 0.7 MPa. Boiler-license-free (total volume <30

CE
Choisir une variante (2)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Electric heating elements heat water inside the boiler vessel to produce saturated steam. Three-level liquid control (high/medium/low) prevents dry-firing. Dual pressure controllers allow adjustable working pressure; protection pressure 0.7 MPa auto-cuts power. Safety valve set at 0.73 MPa (full-lift type) auto-vents on overpressure. Wall temperature sensor >158°C cuts power and triggers audible/visual alarm. Steam output auto starts/stops heating to save energy at low load.

Processus de fonctionnement
1Electric heating elements heat water inside the boiler vessel to produce saturated steam.
2Three-level liquid control (high/medium/low) prevents dry-firing.
3Dual pressure controllers allow adjustable working pressure; protection pressure 0.7 MPa auto-cuts power.
4Safety valve set at 0.73 MPa (full-lift type) auto-vents on overpressure.
5Wall temperature sensor >158°C cuts power and triggers audible/visual alarm.
6Steam output auto starts/stops heating to save energy at low load.

Caractéristiques techniques

Caractéristiques de la variante : SED-18ZQ-J 18 kW / 25 kg/h

Caractéristiques

Modèle
SED-18ZQ-J
Tension
380V 50Hz
Détails de conformité
Total volume <30 L exempts from national boiler operating license; CE certificate provided. Safety valve set at 0.73 MPa; protection pressure 0.7 MPa auto-cut; wall temperature 158°C auto-cut with alarm.
Puissance
18 kW

Dimensions

Longueur
720 mm
Largeur
480 mm
Hauteur
1150 mm

Matériaux

Matériaux en contact
316L thick-wall seamless SS (heating elements); 304 SS (boiler vessel, fittings, valves, pressure gauge)
Matériaux du bâti
304 stainless steel series

Caractéristiques principales

Rated heating power: 18 kW
Rated steam output: 25 kg/h
Saturated steam temperature: 171°C
Rated steam pressure: 0.7 MPa
Steam outlet DN15, water inlet DN15, blowdown outlet DN15
Total volume <30 L (boiler license exemption)
Heating elements: 316L thick-wall seamless SS, high-temp magnesia powder filled, rated to 1000°C, flange-mount removable
LCD boiler controller
Water/electric isolated electrical box (thermal insulation + waterproofing)
Three-level liquid control (high/medium/low) to prevent dry-firing
Dual pressure controllers + protection pressure 0.7 MPa auto-cut
Safety valve set at 0.73 MPa (full-lift type)
Wall temperature >158°C auto power-cut + audible/visual alarm
Auto start/stop on steam demand for energy saving
Dimensions: 720×480×1150 mm
Boiler license exemption (volume <30 L)
CE certificate provided
Water/electric isolated box meets thermal insulation and waterproofing requirements
Full 304 SS boiler vessel + 304 SS fittings/valves
PUNP pure water module
Multiple interlocked safety protections
Factory-tested; user only needs to connect power and water to start
LCD display for all operating data — intuitive and clear

Applications

Small-scale production/lab scenarios requiring clean steam
Clean steam supply in GMP processes

Marques des composants

LCD boiler controller
Rentai Automation
RCCB / air circuit breaker
CHNT
AC contactor and thermal relay
LS Electric
Heating elements 18/24 kW (nitrided)
In-house (316L)
Boiler feed pump 550W SS pump head
Aolong Pump
Safety valve DN15
Guangyi Valve
Steam/blowdown/check valve DN15
Kangtai Valve
Pressure controller PC10
Danfoss
Pressure gauge Y60 1.6 MPa (304)
Shanghai Instrument No.4 Factory
Pure water module
PUNP
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

CE

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→