SED-12SDW-C tunnel-style microwave dryer. Two microwave chambers with top-feed waveguides, 12 kW total microwave power at 2450 +/-50 MHz, segment-adjustable manual or auto. PLC + LCD imaging control, German Optris IR tem

GB10436-89 microwave leakage standardGB16798-1997 food machine hygiene safety standardGB5226 electrical safety standard
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Material rides on a stainless-steel conveyor through a tunnel-shaped chamber housing two microwave generators that feed 2450 MHz energy from the top via standard rectangular waveguides. Toshiba/Panasonic air-cooled magnetrons heat the moisture in the product; vapor rises and is exhausted from the chamber top by a 3 kW centrifugal fan via PVC ducting (bottom-in / top-out airflow design). Inductive comb-tooth + absorber leakage suppressors at both ends keep external leakage below 5 mW/cm^2 at 5 cm. PLC and HMI auto-tune microwave power to maintain set temperature (60-300 degC, configurable per material) using a German Optris IR sensor (15:1 spot ratio). A door-interlock prevents microwave operation while the chamber door is open.

Proceso de funcionamiento
1Material rides on a stainless-steel conveyor through a tunnel-shaped chamber housing two microwave generators that feed 2450 MHz energy from the top via standard rectangular waveguides.
2Toshiba/Panasonic air-cooled magnetrons heat the moisture in the product; vapor rises and is exhausted from the chamber top by a 3 kW centrifugal fan via PVC ducting (bottom-in / top-out airflow design).
3Inductive comb-tooth + absorber leakage suppressors at both ends keep external leakage below 5 mW/cm^2 at 5 cm.
4PLC and HMI auto-tune microwave power to maintain set temperature (60-300 degC, configurable per material) using a German Optris IR sensor (15:1 spot ratio).
5A door-interlock prevents microwave operation while the chamber door is open.

Especificaciones técnicas

Especificaciones de la variante: SED-12SDW-C

Especificaciones

Modelo
SED-12SDW-C
Tensión
Three-phase 5-wire 380 V +/-10% / 50 Hz
Suministros
Three-phase 5-wire 380 V +/-10% / 50 Hz electrical supply; ambient -5 to 45 degC, relative humidity <=80%; no external steam (electric microwave heating)
Detalles de conformidad
Microwave leakage <5 mW/cm^2 at 5 cm gap (GB10436-89). Door-interlock switch prevents microwave operation when chamber door is not fully closed. Chamber opening reinforced to 3 mm to prevent long-term deformation and leakage.
Potencia
12 kW

Dimensiones

Longitud
5600 mm
Anchura
1000 mm
Altura
1700 mm
Superficie de instalación
Overall 5600 x 1000 x 1700 mm

Materiales

Materiales en contacto
SUS304 2B stainless steel (chamber wall delta 2.0 mm, conveyor rollers phi 200 SS main and phi 40 SS auxiliary, mesh belt)
Materiales del cuerpo
SUS304 2B 1.2 mm outer skin; SS square-tube frame (Nangang); chamber opening reinforced to 3 mm thickness

Características principales

Total microwave power 12 kW (2450 +/-50 MHz), segment-adjustable manual/auto
Two microwave chambers with top-feed standard rectangular waveguides
Drying chamber 2.4 x 0.7 x 0.5 m; conveyor with VFD speed
Drying temperature configurable 60-300 degC
PLC + LCD imaging HMI; PLC auto power adjustment
Optris (Germany) IR sensor 0-300 degC, +/-0.1 degC, 15:1 distance ratio
Dual inductive comb-tooth + absorber leakage suppressors (800 mm x 2)
Microwave leakage <5 mW/cm^2 at 5 cm (GB10436-89 compliant)
Bottom-in / top-out humidity exhaust, 3 kW centrifugal fan (500 Pa, 5750 m^3/h)
Door-interlock prevents microwave operation when door open
Imported air-cooled magnetron; Megmeet all-digital intelligent microwave switching power supply
Video monitoring of inside chamber for arcing/jam detection
Inlet air filter on each magnetron to reduce dust ingress
Tunnel design enables continuous, in-line drying
Dual chambers + segment power control allow zoned drying profiles
Compliant with GB10436-89 leakage, GB16798-1997 food-machine hygiene, GB5226 electrical safety
Megmeet digital intelligent power supply - integrated, compact, easy install
Removable rollers and side maintenance/cleaning door for cleaning
Optional water-cooled magnetron + power supply available

Aplicaciones

Continuous tunnel microwave drying
Heat-sensitive material drying with tight temperature control
Food drying conforming to GB16798-1997 hygiene standards
Pharmaceutical / herbal medicine drying

Sectores

Food processing
Pharmaceutical / herbal medicine
Chemical

Marcas de componentes

Zhangpu (Korea) - SUS304 2B sheet (delta 1.2 mm outer / delta 2.0 mm chamber)
Tianmai (Wenzhou) - WB150 motor + reducer
Toshiba / Panasonic (Japan) - magnetrons
Shenzhen - custom microwave-dedicated drive
Optris (Germany) - IR temperature sensor 0-300 degC
Nangang - SS square-tube frame and reinforcement
Nanjing - 200T/220V exhaust fan
Megmeet - all-digital intelligent microwave switching power supply
Shenzhen - video monitoring system
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

GB10436-89 microwave leakage standard
GB16798-1997 food machine hygiene safety standard
GB5226 electrical safety standard

Limpieza y mantenimiento

A side maintenance/cleaning door provides access to the heating chamber for cleaning material residue and servicing the conveyor belt and rollers; chamber lighting installed inside for visibility.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→