SED-1.3-1.7-2.9CLS-Z is a large-volume negative-pressure weighing and sampling booth constructed entirely from SUS304 stainless steel. Overall 1300 × 1700 × 2900 mm (W × D × H); working envelope 1200 × 1200 × 2400 mm — t

Designed to GMP cleanroom standards (Class 100 / ISO 5)On-site particle-count validation
Elegir variante (1)
Plazo de entrega
Consultar
Capacidad de producción
3500–5000 m³/h (rated air flow, range 3500-5000)

Funcionamiento

Two domestic premium centrifugal fans pull air through three-stage filtration: G4 primary (90%@5 µm), F8 medium (97%@1 µm), and ULPA terminal (99.9999%@0.3 µm, liquid-trough sealed). Negative pressure inside the working zone prevents powder escape. Air velocity 0.25–0.6 m/s; illumination 1000 lux; noise ≤ 75 dB. DP gauges (0–500 Pa and 0–250 Pa) monitor filter loading.

Proceso de funcionamiento
1Two domestic premium centrifugal fans pull air through three-stage filtration: G4 primary (90%@5 µm), F8 medium (97%@1 µm), and ULPA terminal (99.9999%@0.3 µm, liquid-trough sealed).
2Negative pressure inside the working zone prevents powder escape.
3Air velocity 0.25–0.6 m/s; illumination 1000 lux; noise ≤ 75 dB.
4DP gauges (0–500 Pa and 0–250 Pa) monitor filter loading.

Especificaciones técnicas

Especificaciones de la variante: SED-1 smaller variant (W1300 × D1300 × H2500

Especificaciones

Modelo
SED-1.3-1.7-2.9CLS-Z
Capacidad de producción
3500–5000 m³/h (rated air flow, range 3500-5000)
Tensión
AC 380V, 50Hz
Suministros
Power: AC 380V, 50 Hz, 2 kW; ambient 5–40 °C, RH ≤ 85% non-condensing
Detalles de conformidad
Built to GMP Class 100 (ISO 5) cleanroom standards; SUS304 throughout. Liquid-trough ULPA seal eliminates bypass leakage. On-site particle-count validation confirms cleanliness at acceptance.
Potencia
2 kW

Dimensiones

Longitud
1300 mm
Anchura
1700 mm
Altura
2900 mm
Superficie de instalación
1300 × 1700 × 2900 mm (W × D × H) overall; working envelope 1200 × 1200 × 2400 mm

Materiales

Materiales en contacto
SUS304 stainless steel (entire enclosure and working surfaces)
Materiales del cuerpo
SUS304 stainless steel throughout

Características principales

Class 100 (ISO 5) cleanliness inside working envelope
Negative-pressure design — operator and environment protection
Overall 1300 × 1700 × 2900 mm (W × D × H); working envelope 1200 × 1200 × 2400 mm
Three-stage filtration: G4 (90%@5 µm) + F8 (97%@1 µm) + ULPA (99.9999%@0.3 µm, liquid-trough sealed)
Rated airflow 3500–5000 m³/h; air velocity 0.25–0.6 m/s
Illumination 1000 lux (higher than compact model)
Noise ≤ 75 dB
Button control; on-site particle-count validation
SUS304 stainless steel throughout; power 2 kW
Larger working envelope (1200 × 1200 mm) handles bigger drums and dispensing volumes
ULPA terminal filter (99.9999%@0.3 µm) — one order of magnitude better than typical HEPA
1000 lux illumination for fine work and label reading
Negative-pressure operator and environment protection
On-site particle-count validation included
12-month free warranty; nationwide service (24 h same-province, 48 h inter-province)

Aplicaciones

Pharmaceutical raw-material weighing (drums, large volumes)
Sampling of raw materials with potent or sensitizing powders
API dispensing operations with larger containers
Containment for hormonal / cytotoxic / β-lactam powder handling

Sectores

Fabricación farmacéutica
API / fine chemical production
Biotechnology

Marcas de componentes

Fans: domestic premium grade (2 units)
ULPA filter: 99.9999%@0.3 µm, liquid-trough sealed
Medium filter: F8 (97%@1 µm)
Primary filter: G4 (90%@5 µm)
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

Designed to GMP cleanroom standards (Class 100 / ISO 5)
On-site particle-count validation

Limpieza y mantenimiento

All-stainless surfaces wipe clean. Replace G4 and F8 filters per schedule. ULPA replacement triggered by DP gauge reaching end-of-life setpoint.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→