Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
SED-60ZQ-T
Auf Anfrage
SED-60ZQ-T
SED · SED-60ZQ-T · Hervorgehoben

SED-60ZQ-T — Electric Steam Generator

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-60ZQ-T 60kW platform-type electric steam generator (high-pressure variant). Rated steam output 86kg/h, saturated steam temperature 192°C, rated pressure 1.2MPa, heat output 51,600 kcal/h. Water capacity below 30L — b

Boiler-use license exempt (water capacity <30L)
Lieferzeit
Auf Anfrage
Durchsatz
86 kg/h

Funktionsweise

After water is loaded, four heating element groups heat the water to produce saturated steam (192°C / 1.2MPa). Steam passes through the built-in steam-water separator inside the drum for dryness before being delivered from the DN20 steam outlet. A pressure controller and safety valve work in tandem: on overpressure the power is cut automatically and/or the valve vents; an extreme low-water-level sensor stops the boiler to prevent dry-burn; leakage protection ensures operator and equipment safety. A four-period timer allows scheduled operation. All states are shown on the LCD.

Prozessbeschreibung
1After water is loaded, four heating element groups heat the water to produce saturated steam (192°C / 1.2MPa).
2Steam passes through the built-in steam-water separator inside the drum for dryness before being delivered from the DN20 steam outlet.
3A pressure controller and safety valve work in tandem: on overpressure the power is cut automatically and/or the valve vents; an extreme low-water-level sensor stops the boiler to prevent dry-burn; leakage protection ensures operator and equipment safety.
4A four-period timer allows scheduled operation.
5All states are shown on the LCD.

Technische Daten

Technische Daten für Variante: SED-60ZQ-T

Technische Daten

Modell
SED-60ZQ-T
Durchsatz
86 kg/h
Spannung
380V 50Hz 3Φ
Leistung
60 kW

Abmessungen

Länge
1050 mm
Breite
600 mm
Höhe
950 mm

Werkstoffe

Kontaktwerkstoffe
316L SS heating tubes; SS drum; copper pipework
Gehäusewerkstoffe
CNC-cut + CNC-folded enclosure; high-temperature powder-coated surface; SS powder-coated water tank

Wesentliche Merkmale

Boiler-use license exempt (water capacity <30L)
High-pressure version: 1.2MPa working pressure, 192°C steam temperature
Built-in steam-water separator for dry steam output
Four independent heating element groups for stepped adjustment
316L thick-wall SS heating tubes + imported high-temperature MgO powder, rated 900°C
Computer-welded PCB control system for reliability
LCD display + four-period timer control
Thermal efficiency ≥98%
X-ray inspection + hydrostatic test before delivery
CNC-cut and CNC-folded enclosure; high-temperature powder-coated
All pipework copper-connected with Delixi (Series 6) electrical components
Boiler feed pump 550W (Aolong); safety valve DN20 (Guangyi)
No boiler-use license required
High-pressure variant (1.2MPa) for higher-temperature process demands
Steam-water separator eliminates wet-steam problems
12-month warranty; lifetime maintenance

Anwendungen

Pharmaceutical sterilisation / process steam
Food steaming / sterilisation
Chemical vessel heating
High-temperature drying equipment pairing

Branchen

Pharma
Lebensmittel und Getränke
Chemical
Health & nutraceuticals

Komponentenhersteller

Leakage breaker / AC contactor (4 groups)
Delixi (Series 6)
Boiler feed pump 550W
Aolong
Safety valve DN20
Guangyi
Steam valve / drain valve / check valve
Yongdexin
Pressure controller (LP12)
Magic / Maijike
Pressure gauge (Y60 1.6MPa)
Zhengbao
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

Boiler-use license exempt (water capacity <30L)

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→