SED-PJSY-A Intelligent Tablet 4-in-1 Tester integrates dissolution, disintegration, hardness, and friability testing in a single instrument. SED series multi-function tablet testers have been used in pharmaceutical analy

IQ/OQ qualification documents (free)
مدة التسليم
حسب الطلب
الطاقة الإنتاجية
تواصل معنا

مبدأ العمل

SED-PJSY-A Intelligent Tablet 4-in-1 Tester integrates dissolution, disintegration, hardness, and friability testing in a single instrument. SED series multi-function tablet testers have been used in pharmaceutical analysis for over 40 years and strictly follow the current Chinese Pharmacopoeia and generic drug consistency evaluation standards. Widely used in pharmaceutical manufacturers, medical R&D, teaching/research, and drug inspection departments. Power: AC220V±10% 50Hz. Temperature control range: room temperature to 45.0 °C(resolution 0.1 °C, accuracy ≤±0.3 °C). Dissolution: 6 channels, paddle run-out ≤0.5 mm, basket run-out ≤1.0 mm, shaft-to-cup axial deviation ≤1.0 mm, speed 10–300 RPM, up to 100 sampling events. Disintegration: 1 basket set(6 tubes), frequency 30–32 cycles/min, amplitude 55±1.0 mm, standard sieve 2.0 mm(optional: 0.42/0.71/1.0 mm). Hardness: 10–350 N, resolution 0.01 N, accuracy ±1.5%±1 digit, diameter 2–25 mm, resolution 0.1 mm, up to 1000 continuous tests. Friability: 1 drum(inner diameter~286 mm, depth 39 mm), default 25 RPM(settable 20–50 RPM), default 100 revolutions(settable 1–1000), clockwise/counterclockwise selectable.

وصف سير العمل
1SED-PJSY-A Intelligent Tablet 4-in-1 Tester integrates dissolution, disintegration, hardness, and friability testing in a single instrument.
2SED series multi-function tablet testers have been used in pharmaceutical analysis for over 40 years and strictly follow the current Chinese Pharmacopoeia and generic drug consistency evaluation standards.
3Widely used in pharmaceutical manufacturers, medical R&D, teaching/research, and drug inspection departments.
4Power: AC220V±10% 50Hz.
5Temperature control range: room temperature to 45.0 °C(resolution 0.1 °C, accuracy ≤±0.3 °C).
6Dissolution: 6 channels, paddle run-out ≤0.5 mm, basket run-out ≤1.0 mm, shaft-to-cup axial deviation ≤1.0 mm, speed 10–300 RPM, up to 100 sampling events.
7Disintegration: 1 basket set(6 tubes), frequency 30–32 cycles/min, amplitude 55±1.0 mm, standard sieve 2.0 mm(optional: 0.42/0.71/1.0 mm).
8Hardness: 10–350 N, resolution 0.01 N, accuracy ±1.5%±1 digit, diameter 2–25 mm, resolution 0.1 mm, up to 1000 continuous tests.
9Friability: 1 drum(inner diameter~286 mm, depth 39 mm), default 25 RPM(settable 20–50 RPM), default 100 revolutions(settable 1–1000), clockwise/counterclockwise selectable.

المواصفات الفنية

مواصفات التكوين: SED-PJSY-A

المواصفات

الطراز
SED-PJSY-A
الجهد
AC220V±10% 50Hz
تفاصيل المطابقة
Compliant with current Chinese Pharmacopoeia and generic drug consistency evaluation standards; free IQ/OQ qualification documents provided.

الخصائص الرئيسية

Four-in-one functions: dissolution, disintegration, hardness, friability
Compact footprint reduces benchtop occupation
Built-in three-level user permission management, audit trail, and test record management
Test reports printable or USB-exportable via device interface
Common sample information management for easy retrieval
High-precision real-time thermostatic control with dual over-temperature protection and temperature calibration
Programmable preheat scheduling — user-set start time
Auto-centering of dissolution vessel and stirrer
Convenient water circulation piping with professional medical-grade quick-connectors
Visible window above hardness chamber for clear test observation
Hardness testing: up to 1000 continuous tests with user-adjustable interval
Free IQ/OQ qualification documents provided
Dissolution: 6 channels, speed 10–300 RPM, ≤100 sampling events
Disintegration: 1 basket set(6 tubes), 30–32 cycles/min, amplitude 55±1.0 mm
Hardness: 10–350 N range, 0.01 N resolution, ±1.5%±1 digit accuracy
Friability: drum inner diameter~286 mm × depth 39 mm, 25 RPM default, 100 revolutions default
Four instruments in one — saves bench space and capital expenditure
40+ year SED series heritage in pharmaceutical analysis
Compliant with current Chinese Pharmacopoeia and generic drug consistency evaluation
Three-level user permissions and audit trail for GMP compliance
Free IQ/OQ documentation

التطبيقات

Tablet dissolution testing
Tablet disintegration time-limit testing
Tablet hardness measurement
Tablet friability testing
Generic drug consistency evaluation
Pharmacopoeia-compliant drug release testing

القطاعات

التصنيع الدوائي
Pharmaceutical R&D
Medical academic and teaching institutions
Drug inspection / regulatory laboratories
SED
تواصل مع SED Sales Team
متخصصو المعدات · تواصل عبر واتساب
استفسر عن مواعيد العمل وتوفر الفريق

الامتثال

IQ/OQ qualification documents(free)

الوثائق

ورقة البيانات (PDF)
نظرة عامة على المعدات والمواصفات والأبعاد · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
دليل التشغيل
التركيب والتشغيل واستكشاف الأعطال · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
ورقة مقارنة (قياسي واقتصادي)
مقارنة التكوينات · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
بروتوكولات IQ / OQ / PQ
وثائق التحقق لمطابقة GMP · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
بروتوكولات FAT / SAT
اختبارات القبول في المصنع وفي الموقع · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
رسومات CAD (STEP / IGES / DWG)
رسومات هندسية لتخطيط المنشأة · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
شهادات المعايرة
مستوى الصوت ومقاومة التأريض والعزل وخشونة السطح · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
DQ (تأهيل التصميم)
بروتوكول كامل لتأهيل التصميم · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
شهادات المواد
تركيب الفولاذ المقاوم للصدأ 316L · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
SED
واتساب · مبيعات SED
التواصل مع المبيعات · واتساب
→