SED-300DKY-F
حسب الطلب
SED-300DKY-F
SED · SED-300DKY-F · مميز
SED-300DKY-F — Nitrogen-Air Integrated Generator
لا تزال ترجمة الوصف الكامل لهذا الطراز قيد العمل. راجع التفاصيل بالإنجليزية أو اطلب المعلومات من فريقنا. English
SED-300DKY-F Combined Nitrogen-and-Air Generator: a single-instrument replacement for nitrogen and zero-air gas cylinders feeding gas chromatograph FID/TCD detectors. Stainless-steel multilayer-plate electrolytic separat
مدة التسليم
حسب الطلب
الطاقة الإنتاجية
تواصل معنا
مبدأ العمل
Nitrogen channel: stainless-steel multilayer plate electrolyser splits air streams to enrich nitrogen, with repeated multi-plate purification raising purity. Air channel: air is compressed and routed through three stages of oil-free purification with two-stage pressure regulation. Both channels output to gas-chromatograph detectors at 0.4 MPa. An anti-back-flow device prevents liquid migration into the instrument.
وصف سير العمل
1Nitrogen channel: stainless-steel multilayer plate electrolyser splits air streams to enrich nitrogen, with repeated multi-plate purification raising purity.
2Air channel: air is compressed and routed through three stages of oil-free purification with two-stage pressure regulation.
3Both channels output to gas-chromatograph detectors at 0.4 MPa.
4An anti-back-flow device prevents liquid migration into the instrument.
المواصفات الفنية
مواصفات التكوين: SED-300DKY-F
المواصفات
الطراز
SED-300DKY-F
الجهد
AC 220V / 50Hz
المرافق
AC 220V / 50Hz, 230 W; periodic distilled-water top-up
القدرة
0.23 kW
ضغط الهواء
0.4 MPa(both N2 and air outlets)
الأبعاد
الطول
520 mm
العرض
280 mm
الارتفاع
400 mm
الوزن
33 kg
المواد
مواد التلامس
Stainless steel multilayer plates(electrolyser); oil-free three-stage purification cartridges
الخصائص الرئيسية
Combines N2 and zero-air generation in a single benchtop unit
N2 purity 99.99%(relative oxygen content); flow 0-300 mL/min
Three-stage oil-free air purification; flow 0-2 L/min
Both outlets at 0.4 MPa
Stainless steel multilayer plate electrolytic separation for N2
Two-stage pressure regulation, multi-level safety protection
LED digital flow display on N2 channel
Anti-back-flow device on N2 line
Daily operation requires only distilled-water replenishment
Independent or simultaneous use of N2 and air
Replaces high-pressure gas cylinders in the lab
Lab-instrument format eliminates compressed-gas cylinder logistics and safety risk
Two gases from one bottle of distilled water
Stable output without purity decay
Simple operation: power-on, gas flowing
التطبيقات
Carrier-gas supply for gas chromatograph(GC) FID detectors
Carrier/auxiliary gas for GC TCD detectors
Replacement of N2 and zero-air cylinders in analytical labs
القطاعات
Pharmaceutical QC labs
Analytical / R&D laboratories
Chemical analysis
SED
تواصل مع SED Sales Team
متخصصو المعدات · تواصل عبر واتساب
استفسر عن مواعيد العمل وتوفر الفريق
الوثائق
ورقة البيانات (PDF)
نظرة عامة على المعدات والمواصفات والأبعاد · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
دليل التشغيل
التركيب والتشغيل واستكشاف الأعطال · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
ورقة مقارنة (قياسي واقتصادي)
مقارنة التكوينات · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
بروتوكولات IQ / OQ / PQ
وثائق التحقق لمطابقة GMP · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
بروتوكولات FAT / SAT
اختبارات القبول في المصنع وفي الموقع · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
رسومات CAD (STEP / IGES / DWG)
رسومات هندسية لتخطيط المنشأة · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
شهادات المعايرة
مستوى الصوت ومقاومة التأريض والعزل وخشونة السطح · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
DQ (تأهيل التصميم)
بروتوكول كامل لتأهيل التصميم · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات
شهادات المواد
تركيب الفولاذ المقاوم للصدأ 316L · المستند الأصلي (الإنجليزية)
اطلب من فريق المبيعات